Multiplex Assay Kit for Heat Shock 70kDa Protein 1A (HSPA1A) ,etc. by FLIA (Flow Luminescence Immunoassay)

HSP70-1; HSP-A1A; HSPA1; HSP70-2; HSX70

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Heat Shock 70kDa Protein 1A (HSPA1A) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Heat Shock 70kDa Protein 1A (HSPA1A) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Heat Shock 70kDa Protein 1A (HSPA1A) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Heat Shock 70kDa Protein 1A (HSPA1A) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 89-98 94
EDTA plasma(n=5) 81-92 88
heparin plasma(n=5) 93-105 97
sodium citrate plasma(n=5) 90-105 98

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Heat Shock 70kDa Protein 1A (HSPA1A) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Heat Shock 70kDa Protein 1A (HSPA1A) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Heat Shock 70kDa Protein 1A (HSPA1A) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 84-98% 84-91% 89-103% 88-95%
EDTA plasma(n=5) 82-91% 79-91% 87-101% 97-105%
heparin plasma(n=5) 98-105% 98-105% 85-103% 79-88%
sodium citrate plasma(n=5) 81-101% 88-97% 88-103% 82-99%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:HSPA1A) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Journal of Neuroinflammation Identification of potential biomarkers of gold nanoparticle toxicity in rat brains PubMed: 22691312
Mediators Inflamm.? Local Inflammation in Fracture Hematoma: Results from a Combined Trauma Model in Pigs Pubmed:Pmc4324980
Eur J Pharmacol. Differential modulatory effects of morphine on acute and chronic stress induced neurobehavioral and cellular markers in rats Pubmed:24508522
Pharmacol Rep. Effect of propranolol on IL-10, visfatin, Hsp70, iNOS, TLR2, and survivin in amelioration of tumor progression and survival in Solid Ehrlich Carcinoma-bearing mice Pubmed:25443743
Advances in Medical Sciences A similar pro/anti-inflammatory cytokine balance is present in the airways of competitive athletes and non-exercising asthmatics pubmed:28822267
Archives of Medical Research Winter ambient training conditions are associated with increased bronchial hyperreactivity and with shifts in serum innate immunity proteins in young … Pubmed:29379533
metabolic brain disease Curcumin attenuates cytoplasmic/endoplasmic reticulum stress, apoptosis and cholinergic dysfunction in diabetic rat hippocampus Pubmed: 32172517
EXPERIMENTAL CELL RESEARCH Antagomirs targeting miR-142–5p attenuate pilocarpine-induced status epilepticus in mice Pubmed: 32439493
Catalog No. Related products for research use of Bos taurus; Bovine (Cattle) Organism species Applications (RESEARCH USE ONLY!)
RPB081Bo01 Recombinant Heat Shock 70kDa Protein 1A (HSPA1A) Positive Control; Immunogen; SDS-PAGE; WB.
PAB081Bo01 Polyclonal Antibody to Heat Shock 70kDa Protein 1A (HSPA1A) WB; IHC; ICC; IP.
LAB081Bo81 FITC-Linked Polyclonal Antibody to Heat Shock 70kDa Protein 1A (HSPA1A) WB; IHC; ICC; IF.
LAB081Bo71 Biotin-Linked Polyclonal Antibody to Heat Shock 70kDa Protein 1A (HSPA1A) WB; IHC; ICC.
MAB081Bo21 Monoclonal Antibody to Heat Shock 70kDa Protein 1A (HSPA1A) WB; IHC; ICC; IP.
SEB081Bo ELISA Kit for Heat Shock 70kDa Protein 1A (HSPA1A) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB081Bo Multiplex Assay Kit for Heat Shock 70kDa Protein 1A (HSPA1A) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSB081Bo01 ELISA Kit DIY Materials for Heat Shock 70kDa Protein 1A (HSPA1A) Main materials for "Do It (ELISA Kit) Yourself".