Multiplex Assay Kit for Urocortin (UCN) ,etc. by CBA (Cytometric Bead Array)
UI; UROC; Urocortin 1; UCN1
- Product No.CMA231Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Sample TypeSerum, plasma and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length3h
- Detection Range0.9766-1000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.3255pg/mL.
- DownloadInstruction Manual
- UOM 48T96T
- FOB
US$ 545
US$ 778
For more details, please contact local distributors!
Specificity
This assay has high sensitivity and excellent specificity for detection of Urocortin (UCN) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Urocortin (UCN) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Urocortin (UCN) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Urocortin (UCN) ,etc. by CBA (Cytometric Bead Array) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 79-96 | 93 |
| EDTA plasma(n=5) | 97-104 | 101 |
| heparin plasma(n=5) | 83-92 | 87 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Urocortin (UCN) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Urocortin (UCN) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Urocortin (UCN) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 80-94% | 93-102% | 86-104% | 93-104% |
| EDTA plasma(n=5) | 91-101% | 86-104% | 80-92% | 97-105% |
| heparin plasma(n=5) | 78-89% | 92-101% | 98-105% | 85-97% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:UCN) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 50μL standard or sample to each well, add 50μL prepared Detection Reagent A, add 10μL magnetic beads, and incubate 90 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
5. Wash plate once on magnetic frame;
6. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
| Magazine | Citations |
| Human Reproduction | P-205 Basement membrane integrity is altered in the late secretary phase in women with endometriosis: implications for the pathogenesis of endometriosis OxfordJournals: source |
| PLOS ONE | Vasoprotective effects of urocortin 1 against atherosclerosis in vitro and in vivo Pubmed:25462164 |
| Taiwan J Obstet Gynecol | Novel markers in the diagnostics of endometriomas: Urocortin, ghrelin, and leptin or leukocytes, fibrinogen, and CA-125? PubMed: 25951715 |
| Biomedical Journal of Scientific & Technical Research | Anti-Inflammatory and Pro-Inflammatory Neuropeptides in Dilative Cardiomyopathy are there Relations to Psychophysical Stress? |
| Neurobiol Stress | Erasing m6A-dependent transcription signature of stress-sensitive genes triggers antidepressant actions 34527794 |
| Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
| RPA231Mu02 | Recombinant Urocortin (UCN) | Positive Control; Immunogen; SDS-PAGE; WB. |
| RPA231Mu01 | Recombinant Urocortin (UCN) | Positive Control; Immunogen; SDS-PAGE; WB. |
| CPA231Mu21 | OVA Conjugated Urocortin (UCN) | Immunogen; SDS-PAGE; WB. |
| PAA231Mu02 | Polyclonal Antibody to Urocortin (UCN) | WB; IHC; ICC; IP. |
| PAA231Mu08 | Polyclonal Antibody to Urocortin (UCN) | Testing in progress. |
| PAA231Mu01 | Polyclonal Antibody to Urocortin (UCN) | WB; IHC; ICC; IP. |
| SEA231Mu | ELISA Kit for Urocortin (UCN) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| CEA231Mu | ELISA Kit for Urocortin (UCN) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| CMA231Mu | Multiplex Assay Kit for Urocortin (UCN) ,etc. by CBA (Cytometric Bead Array) | FLIA Kit for Antigen Detection. |
| LMA231Mu | Multiplex Assay Kit for Urocortin (UCN) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |