Multiplex Assay Kit for Programmed Cell Death Protein 1 (PD1) ,etc. by CBA (Cytometric Bead Array)

CD279; PDCD1; SLEB2; HPD1P

Specificity

This assay has high sensitivity and excellent specificity for detection of Programmed Cell Death Protein 1 (PD1) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Programmed Cell Death Protein 1 (PD1) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Programmed Cell Death Protein 1 (PD1) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Programmed Cell Death Protein 1 (PD1) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-97 88
EDTA plasma(n=5) 96-103 99
heparin plasma(n=5) 80-102 94

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Programmed Cell Death Protein 1 (PD1) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Programmed Cell Death Protein 1 (PD1) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Programmed Cell Death Protein 1 (PD1) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 91-104% 85-94% 80-96% 84-98%
EDTA plasma(n=5) 91-99% 81-96% 94-101% 79-104%
heparin plasma(n=5) 97-105% 95-102% 91-98% 79-98%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Oncotarget Circulating soluble programmed death-1 levels may differentiate immune-tolerant phase from other phases and hepatocellular carcinoma from other clinical diseases in chronic hepatitis B virus infection. pubmed:28545019
CyberLeninka Потенциальные биомаркеры эффективности терапии ниволумабом при метастатическом почечно-клеточном раке :
АНАЛИЗ РЕЗУЛЬТАТОВ ЛЕЧЕНИЯ БОЛЬНЫХ МЕТАСТАТИЧЕСКИМ РАКОМ ПОЧКИ, ПОЛУЧАВШИХ АНТИ-PD-1‑ТЕРАПИЮ В РАМКАХ ПРОГРАММЫ …
International Journal of Molecular Sciences Design and Synthesis of A PD-1 Binding Peptide and Evaluation of Its Anti-Tumor Activity Pubmed: 30699956
PLoS One Clinical significance of soluble programmed cell death-1 and soluble programmed cell death-ligand 1 in patients with locally advanced rectal cancer treated … Pubmed: 30807610
Cancers Predictive Value of Soluble PD-1, PD-L1, VEGFA, CD40 Ligand and CD44 for Nivolumab Therapy in Advanced Non-Small Cell Lung Cancer: A Case-Control Study Pubmed: 32085544
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPA751Mu01 Recombinant Programmed Cell Death Protein 1 (PD1) Positive Control; Immunogen; SDS-PAGE; WB.
SEA751Mu ELISA Kit for Programmed Cell Death Protein 1 (PD1) Enzyme-linked immunosorbent assay for Antigen Detection.
CMA751Mu Multiplex Assay Kit for Programmed Cell Death Protein 1 (PD1) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMA751Mu Multiplex Assay Kit for Programmed Cell Death Protein 1 (PD1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.