Multiplex Assay Kit for Lipase, Hepatic (LIPC) ,etc. by CBA (Cytometric Bead Array)
HL; HTGL; Hepatic Lipase; Hepatic triacylglycerol lipase; Lipase member C
- Product No.CMA769Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length4h
- Detection Range0.0195-20ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.0065ng/mL.
- DownloadInstruction Manual
- UOM 48T96T
- FOB
US$ 545
US$ 778
For more details, please contact local distributors!
Specificity
This assay has high sensitivity and excellent specificity for detection of Lipase, Hepatic (LIPC) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Lipase, Hepatic (LIPC) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Lipase, Hepatic (LIPC) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Lipase, Hepatic (LIPC) ,etc. by CBA (Cytometric Bead Array) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 93-103 | 99 |
| EDTA plasma(n=5) | 90-98 | 95 |
| heparin plasma(n=5) | 84-91 | 88 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Lipase, Hepatic (LIPC) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Lipase, Hepatic (LIPC) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Lipase, Hepatic (LIPC) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 97-105% | 91-99% | 96-105% | 98-105% |
| EDTA plasma(n=5) | 89-96% | 83-96% | 89-97% | 95-104% |
| heparin plasma(n=5) | 86-103% | 97-105% | 95-103% | 93-101% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
| Magazine | Citations |
| The American Journal of Clinical Nutrition | Randomized controlled study of the effect of a butter naturally enriched in trans fatty acids on blood lipids in healthy women1 Ajcn: source |
| J Lipid Res. | Effect of weight loss, independent of change in diet composition, on apolipoprotein AI kinetic in men with metabolic syndrome Pubmed: 23125458 |
| The Korean Journal of Internal Medicine | Clinical efficacy of serum lipase subtype analy-sis for the differential diagnosis of pancreatic and non-pancreatic lipase elevation Pubmed:27243230 |
| The Korean Journal of Internal Medicine | Clinical efficacy of serum lipase subtype analysis for the differential diagnosis of pancreatic and non-pancreatic lipase elevation pubmed:27243230 |
| Journal of Cellular Physiology | Recombinant human hepatocyte growth factor provides protective effects in celurein‐induced acute pancreatitis in mice Pubmed:29341114 |
| Clinical Nutrition ESPEN | Abdominal fat distribution modulates the metabolic effects of exogenous ketones in individuals with new-onset prediabetes after acute pancreatitis: Results from a randomized placebo-controlled trial 34024503 |
| Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
| RPA769Mu01 | Recombinant Lipase, Hepatic (LIPC) | Positive Control; Immunogen; SDS-PAGE; WB. |
| RPA769Mu02 | Recombinant Lipase, Hepatic (LIPC) | Positive Control; Immunogen; SDS-PAGE; WB. |
| RPA769Mu03 | Recombinant Lipase, Hepatic (LIPC) | Positive Control; Immunogen; SDS-PAGE; WB. |
| RPA769Mu04 | Recombinant Lipase, Hepatic (LIPC) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAA769Mu02 | Polyclonal Antibody to Lipase, Hepatic (LIPC) | Testing in progress. |
| PAA769Mu01 | Polyclonal Antibody to Lipase, Hepatic (LIPC) | IHC |
| LAA769Mu71 | Biotin-Linked Polyclonal Antibody to Lipase, Hepatic (LIPC) | WB; IHC; ICC. |
| LAA769Mu81 | FITC-Linked Polyclonal Antibody to Lipase, Hepatic (LIPC) | WB; IHC; ICC; IF. |
| SEA769Mu | ELISA Kit for Lipase, Hepatic (LIPC) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| LMA769Mu | Multiplex Assay Kit for Lipase, Hepatic (LIPC) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
| CMA769Mu | Multiplex Assay Kit for Lipase, Hepatic (LIPC) ,etc. by CBA (Cytometric Bead Array) | FLIA Kit for Antigen Detection. |