Multiplex Assay Kit for Inducible T-Cell Co Stimulator Ligand (ICOSLG) ,etc. by CBA (Cytometric Bead Array)

CD275; B7-H2; B7H2; B7RP-1; B7RP1; GL50; ICOS-L; ICOSL; LICOS; B7-like protein Gl50; B7-related protein 1

Specificity

This assay has high sensitivity and excellent specificity for detection of Inducible T-Cell Co Stimulator Ligand (ICOSLG) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Inducible T-Cell Co Stimulator Ligand (ICOSLG) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Inducible T-Cell Co Stimulator Ligand (ICOSLG) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Inducible T-Cell Co Stimulator Ligand (ICOSLG) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-98 82
EDTA plasma(n=5) 81-98 88
heparin plasma(n=5) 94-101 97

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Inducible T-Cell Co Stimulator Ligand (ICOSLG) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Inducible T-Cell Co Stimulator Ligand (ICOSLG) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Inducible T-Cell Co Stimulator Ligand (ICOSLG) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 79-104% 78-93% 80-91% 91-99%
EDTA plasma(n=5) 91-101% 99-105% 82-98% 97-104%
heparin plasma(n=5) 87-95% 89-99% 80-89% 98-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
中华疾病控制杂志 可诱导共刺激分子配体在系统性红斑狼疮血清中水平及临床意义 2f4qfivv.pdf
Br J Haematol Inducible T‐cell co‐stimulator (ICOS) and ICOS ligand are novel players in the multiple‐myeloma microenvironment Pubmed:34954822
Diagnostics (Basel) Increased Levels of ICOS and ICOSL Are Associated to Pulmonary Arterial Hypertension in Patients Affected by Connective Tissue Diseases Pubmed:35328257
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
EPA787Hu62 Eukaryotic Inducible T-Cell Co Stimulator Ligand (ICOSLG) Positive Control; Immunogen; SDS-PAGE; WB.
RPA787Hu01 Recombinant Inducible T-Cell Co Stimulator Ligand (ICOSLG) Positive Control; Immunogen; SDS-PAGE; WB.
EPA787Hu61 Eukaryotic Inducible T-Cell Co Stimulator Ligand (ICOSLG) Positive Control; Immunogen; SDS-PAGE; WB.
PAA787Hu01 Polyclonal Antibody to Inducible T-Cell Co Stimulator Ligand (ICOSLG) IHC
FAA787Hu01 Anti-Inducible T-Cell Co Stimulator Ligand (ICOSLG) Polyclonal Antibody Flow cytometry.
MAA787Hu22 Monoclonal Antibody to Inducible T-Cell Co Stimulator Ligand (ICOSLG) WB
MAA787Hu21 Monoclonal Antibody to Inducible T-Cell Co Stimulator Ligand (ICOSLG) WB
SEA787Hu ELISA Kit for Inducible T-Cell Co Stimulator Ligand (ICOSLG) Enzyme-linked immunosorbent assay for Antigen Detection.
CMA787Hu Multiplex Assay Kit for Inducible T-Cell Co Stimulator Ligand (ICOSLG) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMA787Hu Multiplex Assay Kit for Inducible T-Cell Co Stimulator Ligand (ICOSLG) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.