Multiplex Assay Kit for Vitamin C (VC) ,etc. by CBA (Cytometric Bead Array)

AA; L-Ascorbic Acid; Ascorbate

Specificity

This assay has high sensitivity and excellent specificity for detection of Vitamin C (VC) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Vitamin C (VC) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of Vitamin C (VC) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Vitamin C (VC) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 91-99 95
EDTA plasma(n=5) 82-92 86
heparin plasma(n=5) 78-90 82

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Vitamin C (VC) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Vitamin C (VC) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Vitamin C (VC) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 95-102% 82-97% 85-93% 97-105%
EDTA plasma(n=5) 81-92% 87-97% 90-101% 79-102%
heparin plasma(n=5) 84-93% 89-99% 79-95% 79-91%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:VC) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 50μL standard or sample to each well, add 50μL prepared Detection Reagent A, add 10μL magnetic beads, and incubate 90 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
5. Wash plate once on magnetic frame;
6. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
BioMed Research International Salivary 1, 5-Anhydroglucitol and Vitamin Levels in Relation to Caries Risk in Children
Vitamin A, C, D, E and B12 Levels in Leprosy: A Case Control Study
Nutrients Vitamin C¡ªSources, Physiological Role, Kinetics, Deficiency, Use, Toxicity, and Determination 33668681
Catalog No. Related products for research use of Pan-species (General) Organism species Applications (RESEARCH USE ONLY!)
CPA913Ge11 BSA Conjugated Vitamin C (VC) Immunogen; SDS-PAGE; WB.
CPA913Ge21 OVA Conjugated Vitamin C (VC) Immunogen; SDS-PAGE; WB.
PAA913Ge01 Polyclonal Antibody to Vitamin C (VC) ELISA
LAA913Ge71 Biotin-Linked Polyclonal Antibody to Vitamin C (VC) WB; IHC; ICC.
MAA913Ge21 Monoclonal Antibody to Vitamin C (VC) ELISA
CEA913Ge ELISA Kit for Vitamin C (VC) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA913Ge Multiplex Assay Kit for Vitamin C (VC) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMA913Ge Multiplex Assay Kit for Vitamin C (VC) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
KSA913Ge11 ELISA Kit DIY Materials for Vitamin C (VC) Main materials for "Do It (ELISA Kit) Yourself".