Multiplex Assay Kit for 25-Hydroxyvitamin D3 (HVD3) ,etc. by CBA (Cytometric Bead Array)
25-HVD3; 25HVD3; Calcifediol; Calcidiol; H-VD3; 25-Hydroxycholecalciferol; 25-Hydroxy Vitamin D3; 25(OH)D
- Product No.CMA915Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- Sample TypeSerum, plasma and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length3h
- Detection Range0.4883-500ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.1628ng/mL.
- DownloadInstruction Manual
- UOM 48T96T
- FOB
US$ 669
US$ 955
For more details, please contact local distributors!
Specificity
This assay has high sensitivity and excellent specificity for detection of 25-Hydroxyvitamin D3 (HVD3) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between 25-Hydroxyvitamin D3 (HVD3) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of 25-Hydroxyvitamin D3 (HVD3) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of 25-Hydroxyvitamin D3 (HVD3) ,etc. by CBA (Cytometric Bead Array) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 92-99 | 95 |
| EDTA plasma(n=5) | 78-97 | 83 |
| heparin plasma(n=5) | 79-102 | 84 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level 25-Hydroxyvitamin D3 (HVD3) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level 25-Hydroxyvitamin D3 (HVD3) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of 25-Hydroxyvitamin D3 (HVD3) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 91-101% | 90-97% | 98-105% | 80-101% |
| EDTA plasma(n=5) | 94-102% | 87-96% | 78-92% | 80-104% |
| heparin plasma(n=5) | 78-96% | 81-99% | 79-89% | 91-101% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:HVD3) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 50μL standard or sample to each well, add 50μL prepared Detection Reagent A, add 10μL magnetic beads, and incubate 90 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
5. Wash plate once on magnetic frame;
6. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
| Magazine | Citations |
| Allergy & Clinical Immunology | Decreased serum LL-37 and vitamin D3 levels in atopic dermatitis: relationship between IL-31 and oncostatin M Wiley: source |
| Tianjin Med J | 成人哮喘血清维生素D 水平与肺功能相关因素分析 Jwk_Tjyy: Cn |
| Journal of Functional Foods | Comparative effects of brown and golden flaxseeds on body composition, inflammation and bone remodelling biomarkers in perimenopausal overweight women S1756464617301561 |
| J Nutr Biochem. | Chronic maternal calcium and 25-hydroxyvitamin D deficiency in Wistar rats programs abnormal hepatic gene expression leading to hepatic steatosis in female offspring. pubmed:28219837 |
| in vivo | Effect of Calcitriol on FGF23 Level in Healthy Adults and its Dependence on Phosphate Level pubmed:28064234 |
| Asia pacific allergy | Serum 25-hydroxyvitamin D inversely associated with blood eosinophils in patients with persistent allergic rhinitis. pubmed:29094019 |
| Biomed Research International | Effects of Vitamin D Restricted Diet Administered during Perinatal and Postnatal Periods on the Penis of Wistar Rats Pubmed:29850540 |
| Clin Implant Dent Relat Res. | Evaluation of FGF‐23 and 25(OH)D3 levels in peri‐implant sulcus fluid in peri‐implant health and diseases Pubmed: 31407857 |
| JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY | Circulating Osteocyte‐Related Biomarkers (vitamin D, sclerostin, dickkopf-1), hepcidin, and oxidative stress markers in early breast cancer: their impact in … Pubmed: 33065276 |
| The Journal of Obstetrics and Gynecology of India | The Effects of Follicular Fluid 25 (OH) D Concentration on Intrafollicular Estradiol Level, Oocyte Quality, and Fertilization Rate in Women Who Underwent IVF Program |