Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Angiopoietin Like Protein 4 (ANGPTL4) ,etc. by CBA (Cytometric Bead Array)
ARP4; FIAF; HFARP; NL2; PGAR; Pp1158; Fasting-Induced Adipose Factor; Hepatic Angiopoietin-Related Protein; Hepatic Fibrinogen/Angiopoietin-Related Protein
- Product No.CMB019Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length4h
- Detection Range0.0098-10ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.0033ng/mL.
- DownloadInstruction Manual
- UOM 48T96T
- FOB
US$ 575
US$ 821
For more details, please contact local distributors!
Specificity
This assay has high sensitivity and excellent specificity for detection of Angiopoietin Like Protein 4 (ANGPTL4) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Angiopoietin Like Protein 4 (ANGPTL4) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Angiopoietin Like Protein 4 (ANGPTL4) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Angiopoietin Like Protein 4 (ANGPTL4) ,etc. by CBA (Cytometric Bead Array) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 87-101 | 97 |
| EDTA plasma(n=5) | 89-96 | 92 |
| heparin plasma(n=5) | 99-105 | 102 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Angiopoietin Like Protein 4 (ANGPTL4) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Angiopoietin Like Protein 4 (ANGPTL4) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Angiopoietin Like Protein 4 (ANGPTL4) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 81-96% | 93-101% | 96-104% | 78-104% |
| EDTA plasma(n=5) | 80-103% | 78-93% | 87-95% | 80-92% |
| heparin plasma(n=5) | 78-99% | 87-94% | 92-99% | 94-101% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
| Magazine | Citations |
| The Journal of Biological Chemistry | Angiopoietin-like 4 (Angptl4) Protein Is a Physiological Mediator of Intracellular Lipolysis in Murine Adipocytes PubMed: PMC3318686 |
| J Clin Endocrinol Metab. | Decreased Concentrations of the Lipoprotein Lipase Inhibitor Angiopoietin-Like Protein 4 and Increased Serum Triacylglycerol Are Associated With Increased Neonatal Fat Mass in Pregnant Women With Gestational Diabetes Mellitus Pubmed: 23744407 |
| PloS one | Lack of Relationship between Cord Serum Angiopoietin-Like Protein 4 (ANGPTL4) and Lipolytic Activity in Human Neonates Born by Spontaneous Delivery Pubmed: 24324678 |
| Journal of Hematology & Oncology | Angptl4 is upregulated under inflammatory conditions in the bone marrow of mice, expands myeloid progenitors, and accelerates reconstitution of platelets after myelosuppressive therapy PubMed: 26054961 |
| Gynecol Endocrinol | Examination of angiopoietin-like protein 4, neuropeptide Y, omentin-1 levels of obese and non-obese patients with polycystic ovary syndrome PubMed: 26291814 |
| Molecular Nutrition & Food research | Interaction of Gut Microbiota and High‐sodium, Low‐potassium Diet in Altering Plasma Triglyceride Profiles Revealed by Lipidomics Analysis Pubmed: 31675161 |
| ANNALS OF AGRICULTURAL AND ENVIRONMENTAL MEDICINE | Analysis of novel serum markers of fibrosis and angiogenesis in patients with alcoholic liver cirrhosis |
| Food Chem Toxicol | Di (2-ethylhexyl) phthalate exposure exacerbates metabolic disorders in diet-induced obese mice 34303773 |

