Multiplex Assay Kit for Alanine Aminopeptidase (AAP) ,etc. by CBA (Cytometric Bead Array)

CD13; ALAP; P150; ANPEP; APN; LAP1; PEPN; Gp150; Aminopeptidase M; Microsomal Aminopeptidase; Alanyl Membrane Aminopeptidase; Aminopeptidase N

Specificity

This assay has high sensitivity and excellent specificity for detection of Alanine Aminopeptidase (AAP) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Alanine Aminopeptidase (AAP) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Alanine Aminopeptidase (AAP) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Alanine Aminopeptidase (AAP) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 81-103 90
EDTA plasma(n=5) 88-104 97
heparin plasma(n=5) 82-97 87

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Alanine Aminopeptidase (AAP) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Alanine Aminopeptidase (AAP) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Alanine Aminopeptidase (AAP) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 89-96% 91-99% 89-103% 81-94%
EDTA plasma(n=5) 80-96% 84-93% 79-102% 96-105%
heparin plasma(n=5) 87-101% 82-105% 97-105% 78-91%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Life Sciences Adipose tissue regulates hepatic cholesterol metabolism via adiponectin Pubmed:25445438
Sci Rep. Genomic reprograming analysis of the Mesothelial to Mesenchymal Transition identifies biomarkers in peritoneal dialysis patients. pubmed:28327551
Analytical Chemistry In Vivo Two-Photon Fluorescence Imaging of the Activity of the Inflammatory Biomarker LTAH in a Mouse Pneumonia Model Pubmed:29682967
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
EPB065Hu61 Eukaryotic Alanine Aminopeptidase (AAP) Positive Control; Immunogen; SDS-PAGE; WB.
APB065Hu61 Active Alanine Aminopeptidase (AAP) Cell culture; Activity Assays.
RPB065Hu01 Recombinant Alanine Aminopeptidase (AAP) Positive Control; Immunogen; SDS-PAGE; WB.
RPB065Hu02 Recombinant Alanine Aminopeptidase (AAP) Positive Control; Immunogen; SDS-PAGE; WB.
PAB065Hu01 Polyclonal Antibody to Alanine Aminopeptidase (AAP) WB; IHC
MAB065Hu21 Monoclonal Antibody to Alanine Aminopeptidase (AAP) WB
MAB065Hu22 Monoclonal Antibody to Alanine Aminopeptidase (AAP) WB
MAB065Hu26 Monoclonal Antibody to Alanine Aminopeptidase (AAP) WB
FAB065Hu02 Anti-Alanine Aminopeptidase (AAP) Monoclonal Antibody FCM
FAB065Hu04 Anti-Alanine Aminopeptidase (AAP) Monoclonal Antibody FCM
SEB065Hu ELISA Kit for Alanine Aminopeptidase (AAP) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB065Hu Multiplex Assay Kit for Alanine Aminopeptidase (AAP) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMB065Hu Multiplex Assay Kit for Alanine Aminopeptidase (AAP) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.