Multiplex Assay Kit for Fc Fragment Of IgA Receptor (FcaR) ,etc. by CBA (Cytometric Bead Array)

CD89; FcaRI; Receptor I For The Fc Region Of Immunoglobulin A; IgA Fc receptor; Immunoglobulin alpha Fc receptor

Specificity

This assay has high sensitivity and excellent specificity for detection of Fc Fragment Of IgA Receptor (FcaR) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Fc Fragment Of IgA Receptor (FcaR) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Fc Fragment Of IgA Receptor (FcaR) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Fc Fragment Of IgA Receptor (FcaR) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 94-101 98
EDTA plasma(n=5) 82-92 89
heparin plasma(n=5) 96-105 102

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Fc Fragment Of IgA Receptor (FcaR) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Fc Fragment Of IgA Receptor (FcaR) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Fc Fragment Of IgA Receptor (FcaR) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 99-105% 79-91% 80-101% 87-99%
EDTA plasma(n=5) 89-103% 86-94% 94-102% 81-105%
heparin plasma(n=5) 84-99% 92-101% 83-98% 81-102%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
BBA Clinical Urinary myeloid IgA Fc alpha receptor (CD89) and transglutaminase-2 as new biomarkers for active IgA nephropathy and henoch-Schönlein purpura nephritis Pubmed:27051593
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPB402Hu01 Recombinant Fc Fragment Of IgA Receptor (FcaR) Positive Control; Immunogen; SDS-PAGE; WB.
PAB402Hu01 Polyclonal Antibody to Fc Fragment Of IgA Receptor (FcaR) WB
FAB402Hu01 Anti-Fc Fragment Of IgA Receptor (FcaR) Polyclonal Antibody Flow cytometry.
MAB402Hu22 Monoclonal Antibody to Fc Fragment Of IgA Receptor (FcaR) WB; IHC; ICC; IP.
SEB402Hu ELISA Kit for Fc Fragment Of IgA Receptor (FcaR) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB402Hu Multiplex Assay Kit for Fc Fragment Of IgA Receptor (FcaR) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMB402Hu Multiplex Assay Kit for Fc Fragment Of IgA Receptor (FcaR) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.