Multiplex Assay Kit for Cofilin 1 (CFL1) ,etc. by CBA (Cytometric Bead Array)

CFL; p18; N-Cofilin; 18 kDa phosphoprotein; Cofilin 1, Non Muscle

Specificity

This assay has high sensitivity and excellent specificity for detection of Cofilin 1 (CFL1) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Cofilin 1 (CFL1) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Cofilin 1 (CFL1) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Cofilin 1 (CFL1) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 96-105 101
EDTA plasma(n=5) 80-91 83
heparin plasma(n=5) 80-104 98

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cofilin 1 (CFL1) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cofilin 1 (CFL1) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Cofilin 1 (CFL1) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 83-99% 79-95% 88-102% 96-104%
EDTA plasma(n=5) 90-104% 93-105% 93-101% 95-103%
heparin plasma(n=5) 84-98% 98-105% 80-101% 96-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Brazilian Journal of Medical and Biological Research Detection of sputum cofilin-1 as indicator of malignancy Pubmed:29846436
Nutrients Hydroxytyrosol as a Promising Ally in the Treatment of Fibromyalgia Pubmed: 32784915
The level of cytoskeleton remodeling proteins in the blood serum and the expression of their mRNA in the tumor tissue in metastasis of the larynx and hypopharynx cancer
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPB559Mu01 Recombinant Cofilin 1 (CFL1) Positive Control; Immunogen; SDS-PAGE; WB.
RPB559Mu02 Recombinant Cofilin 1 (CFL1) Positive Control; Immunogen; SDS-PAGE; WB.
PAB559Mu01 Polyclonal Antibody to Cofilin 1 (CFL1) WB; IHC; ICC; IP.
PAB559Mu02 Polyclonal Antibody to Cofilin 1 (CFL1) WB; IHC; ICC; IP.
SEB559Mu ELISA Kit for Cofilin 1 (CFL1) Enzyme-linked immunosorbent assay for Antigen Detection.
SCB559Mu CLIA Kit for Cofilin 1 (CFL1) Chemiluminescent immunoassay for Antigen Detection.
LMB559Mu Multiplex Assay Kit for Cofilin 1 (CFL1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMB559Mu Multiplex Assay Kit for Cofilin 1 (CFL1) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.