Multiplex Assay Kit for UDP Glucose Ceramide Glucosyltransferase (UGCG) ,etc. by CBA (Cytometric Bead Array)

GCS; GLCT-1; Glucosylceramide Synthase; N-acylsphingosine D-glucosyltransferase

Specificity

This assay has high sensitivity for detection of UDP Glucose Ceramide Glucosyltransferase (UGCG) ,etc. by CBA (Cytometric Bead Array).
100% cross-reactivity of UDP Glucose Ceramide Glucosyltransferase (UGCG) ,etc. by CBA (Cytometric Bead Array) was observed among Human, Mouse, Rat.

Recovery

Matrices listed below were spiked with certain level of recombinant UDP Glucose Ceramide Glucosyltransferase (UGCG) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of UDP Glucose Ceramide Glucosyltransferase (UGCG) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 88-96 92
EDTA plasma(n=5) 85-92 89
heparin plasma(n=5) 80-102 93

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level UDP Glucose Ceramide Glucosyltransferase (UGCG) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level UDP Glucose Ceramide Glucosyltransferase (UGCG) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of UDP Glucose Ceramide Glucosyltransferase (UGCG) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 87-96% 80-94% 79-89% 82-103%
EDTA plasma(n=5) 78-97% 88-96% 80-98% 86-104%
heparin plasma(n=5) 98-105% 81-89% 87-94% 98-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Catalog No. Related products for research use of Homo sapiens (Human), Mus musculus (Mouse), Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
APB742Mi01 Active UDP Glucose Ceramide Glucosyltransferase (UGCG) Cell culture; Activity Assays.
RPB742Mi01 Recombinant UDP Glucose Ceramide Glucosyltransferase (UGCG) Positive Control; Immunogen; SDS-PAGE; WB.
PAB742Mi01 Polyclonal Antibody to UDP Glucose Ceramide Glucosyltransferase (UGCG) WB; IHC
SEB742Mi ELISA Kit for UDP Glucose Ceramide Glucosyltransferase (UGCG) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB742Mi Multiplex Assay Kit for UDP Glucose Ceramide Glucosyltransferase (UGCG) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMB742Mi Multiplex Assay Kit for UDP Glucose Ceramide Glucosyltransferase (UGCG) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.