Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Neprilysin (CD10) ,etc. by CBA (Cytometric Bead Array)
NEP; MME; CALLA; SFE; Atriopeptidase; Enkephalinase; Skin fibroblast elastase; Common Acute Lymphoblastic Leukemia Antigen; Membrane Metallo-Endopeptidase
- Product No.CMB785Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length4h
- Detection Range4.8828-5000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 1.6276pg/mL.
- DownloadInstruction Manual
- UOM 48T96T
- FOB
US$ 606
US$ 866
For more details, please contact local distributors!
Specificity
This assay has high sensitivity and excellent specificity for detection of Neprilysin (CD10) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Neprilysin (CD10) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Neprilysin (CD10) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Neprilysin (CD10) ,etc. by CBA (Cytometric Bead Array) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 92-101 | 95 |
| EDTA plasma(n=5) | 78-95 | 87 |
| heparin plasma(n=5) | 88-95 | 92 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Neprilysin (CD10) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Neprilysin (CD10) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Neprilysin (CD10) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 88-95% | 92-99% | 98-105% | 92-101% |
| EDTA plasma(n=5) | 80-92% | 85-101% | 84-94% | 78-104% |
| heparin plasma(n=5) | 81-93% | 89-97% | 90-101% | 94-102% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
| Magazine | Citations |
| 13 | Elevated Plasma levels of Neutral Endpeptidase in Hypertension Patients Treated with Angiotensin Converting Enzyme Inhibitors Ahajournals:Source |
| Biol Pharm Bull | Effect of High Glucose Levels on Amyloid β Production in Retinas of Spontaneous Diabetes Mellitus Otsuka Long-Evans Tokushima Fatty Rats PubMed: 25832640 |
| Eur J Heart Fail. | Soluble neprilysin does not correlate with outcome in heart failure with preserved ejection fraction Pubmed:26725876 |
| 8 | A Test in Context: Neprilysin: Function, Inhibition, and Biomarker. pubmed:27491909 |
| European Journal of Heart Failure | Effects of sacubitril/valsartan on neprilysin targets and the metabolism of natriuretic peptides in chronic heart failure: a mechanistic clinical study Pubmed: 30520545 |
| European Journal of Heart Failure | Increased granulocyte membrane neprilysin (CD10) expression is associated with better prognosis in heart failure Pubmed: 30828920 |
| Clinical Research in Cardiology | Soluble neprilysin, NT-proBNP, and growth differentiation factor-15 as biomarkers for heart failure in dialysis patients (SONGBIRD) Pubmed: 32002632 |
| Neurotoxicology | Involvement of hippocampal agmatine in β1-42 amyloid induced memory impairment, neuroinflammation and BDNF signaling disruption in mice Pubmed: 32522471 |
| European Heart Journal | P1620 Association of granulocyte neprilysin (CD10) expression with prognosis in heart failure with reduced ejection fraction |
| Clin Biochem | Finding a reliable assay for soluble neprilysin Pubmed:35331754 |
| Scientific Reports | The potential role of serum tau protein (MAPT), neuronal cell adhesion molecule (NrCAM) and neprilysin (NEP) in neurodegenerative disorders development in … |
| Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
| RPB785Ra03 | Recombinant Neprilysin (CD10) | Positive Control; Immunogen; SDS-PAGE; WB. |
| RPB785Ra02 | Recombinant Neprilysin (CD10) | Positive Control; Immunogen; SDS-PAGE; WB. |
| RPB785Ra01 | Recombinant Neprilysin (CD10) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAB785Ra01 | Polyclonal Antibody to Neprilysin (CD10) | IHC |
| PAB785Ra02 | Polyclonal Antibody to Neprilysin (CD10) | IHC |
| LAB785Ra71 | Biotin-Linked Polyclonal Antibody to Neprilysin (CD10) | IHC |
| SEB785Ra | ELISA Kit for Neprilysin (CD10) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| CMB785Ra | Multiplex Assay Kit for Neprilysin (CD10) ,etc. by CBA (Cytometric Bead Array) | FLIA Kit for Antigen Detection. |
| LMB785Ra | Multiplex Assay Kit for Neprilysin (CD10) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |