Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Fetuin B (FETUB) ,etc. by CBA (Cytometric Bead Array)
FETU-B; 16G2; Gugu; IRL685; Fetuin-like protein IRL685
- Product No.CMB860Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample Typeserum, plasma and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length4h
- Detection Range7.8125-8000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 2.6042pg/mL.
- DownloadInstruction Manual
- UOM 48T96T
- FOB
US$ 559
US$ 798
For more details, please contact local distributors!
Specificity
This assay has high sensitivity and excellent specificity for detection of Fetuin B (FETUB) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Fetuin B (FETUB) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Fetuin B (FETUB) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Fetuin B (FETUB) ,etc. by CBA (Cytometric Bead Array) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 90-97 | 94 |
| EDTA plasma(n=5) | 89-98 | 94 |
| heparin plasma(n=5) | 89-96 | 93 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Fetuin B (FETUB) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Fetuin B (FETUB) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Fetuin B (FETUB) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 81-95% | 98-105% | 84-93% | 98-105% |
| EDTA plasma(n=5) | 97-104% | 79-96% | 95-102% | 96-104% |
| heparin plasma(n=5) | 94-105% | 86-93% | 83-97% | 78-95% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
| Magazine | Citations |
| Endocrine | Serum fetuin B level increased in subjects of nonalcoholic fatty liver disease: a case-control study pubmed:27628583 |
| Endocrine | Increased serum levels of fetuin B in patients with coronary artery disease pubmed:28822077 |
| DIABETES & METABOLISM | Plasma fetuin-B concentrations are associated with insulin resistance and first-phase glucose-stimulated insulin secretion in individuals with different degrees of … Pubmed:29514765 |
| Clinical & Investigative Medicine | Serum level of fetuin B is associated with osteoporosis: a 4-year prospective study in China Pubmed:29603688 |
| American Journal of Translational Research | Fetuin B aggravates liver X receptor-mediated hepatic steatosis through AMPK in HepG2 cells and mice Pubmed: 30972177 |
| Endocrine Connections | Increased serum fetuin-B concentration is associated with HOMA-β and indices of liver steatosis in women with polycystic ovary syndrome: a pilot study Pubmed: 31307012 |
| J Transl Med | Multi-omic signatures of atherogenic dyslipidaemia: pre-clinical target identification and validation in humans 33407555 |
| J Nephrol | Citrate high volume on-line hemodiafiltration modulates serum Interleukin-6 and Klotho levels: the multicenter randomized controlled study ¡°Hephaestus¡± 33559851 |
| Nutrients | High Fat, High Sugar Diet and DJOS Bariatric Surgery Influence Plasma Levels of Fetuin-B, Growth Differentiation Factor-15, and Pentraxin 3 in Diet-Induced Obese … 34684637 |
| Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
| RPB860Hu01 | Recombinant Fetuin B (FETUB) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAB860Hu01 | Polyclonal Antibody to Fetuin B (FETUB) | WB |
| LAB860Hu81 | FITC-Linked Polyclonal Antibody to Fetuin B (FETUB) | WB; IHC; ICC; IF. |
| LAB860Hu71 | Biotin-Linked Polyclonal Antibody to Fetuin B (FETUB) | WB; IHC; ICC. |
| MAB860Hu22 | Monoclonal Antibody to Fetuin B (FETUB) | WB; IHC; ICC; IP. |
| SEB860Hu | ELISA Kit for Fetuin B (FETUB) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| LMB860Hu | Multiplex Assay Kit for Fetuin B (FETUB) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
| CMB860Hu | Multiplex Assay Kit for Fetuin B (FETUB) ,etc. by CBA (Cytometric Bead Array) | FLIA Kit for Antigen Detection. |

