Multiplex Assay Kit for Coagulation Factor VII (F7) ,etc. by CBA (Cytometric Bead Array)

FVII; SPCA; proconvertin; Cothromboplastin; Serum Prothrombin Conversation Accelerator; Stable Factor; Eptacog alfa

Specificity

This assay has high sensitivity and excellent specificity for detection of Coagulation Factor VII (F7) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Coagulation Factor VII (F7) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Coagulation Factor VII (F7) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Coagulation Factor VII (F7) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 90-97 94
EDTA plasma(n=5) 84-98 88
heparin plasma(n=5) 81-94 88

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Coagulation Factor VII (F7) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Coagulation Factor VII (F7) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Coagulation Factor VII (F7) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 87-102% 94-103% 91-98% 79-97%
EDTA plasma(n=5) 94-102% 90-101% 86-94% 93-101%
heparin plasma(n=5) 89-96% 98-105% 80-101% 81-97%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Am J Physiol Heart Circ Physiol. Monocytes regulate systemic coagulation and inflammation in abdominal sepsis Pubmed:25502108
Perfusion Ex vivo simulation of cardiopulmonary bypass with human blood for hemocompatibility testing PubMed: 26243277
Cardiovascular Research Loss of accelerates arterial thrombosis by increasing formation of neutrophil extracellular traps and plasma tissue factor activity Pubmed:29444200
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPB874Mu01 Recombinant Coagulation Factor VII (F7) Positive Control; Immunogen; SDS-PAGE; WB.
RPB874Mu02 Recombinant Coagulation Factor VII (F7) Positive Control; Immunogen; SDS-PAGE; WB.
PAB874Mu02 Polyclonal Antibody to Coagulation Factor VII (F7) WB; IHC; ICC/IF
PAB874Mu01 Polyclonal Antibody to Coagulation Factor VII (F7) WB; IHC
LAB874Mu71 Biotin-Linked Polyclonal Antibody to Coagulation Factor VII (F7) WB
HEB874Mu High Sensitive ELISA Kit for Coagulation Factor VII (F7) Enzyme-linked immunosorbent assay for Antigen Detection.
SEB874Mu ELISA Kit for Coagulation Factor VII (F7) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB874Mu Multiplex Assay Kit for Coagulation Factor VII (F7) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMB874Mu Multiplex Assay Kit for Coagulation Factor VII (F7) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
KSB874Mu01 ELISA Kit DIY Materials for Coagulation Factor VII (F7) Main materials for "Do It (ELISA Kit) Yourself".