Multiplex Assay Kit for Sorting Nexin 13 (SNX13) ,etc. by CBA (Cytometric Bead Array)

RGS-PX1; RGS domain- and PHOX domain-containing protein

Specificity

This assay has high sensitivity and excellent specificity for detection of Sorting Nexin 13 (SNX13) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Sorting Nexin 13 (SNX13) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Sorting Nexin 13 (SNX13) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Sorting Nexin 13 (SNX13) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 79-102 83
EDTA plasma(n=5) 84-101 91
heparin plasma(n=5) 93-101 96

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Sorting Nexin 13 (SNX13) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Sorting Nexin 13 (SNX13) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Sorting Nexin 13 (SNX13) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 81-95% 81-104% 97-105% 78-104%
EDTA plasma(n=5) 94-102% 80-89% 79-101% 83-93%
heparin plasma(n=5) 84-105% 92-104% 87-98% 78-95%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPC195Hu01 Recombinant Sorting Nexin 13 (SNX13) Positive Control; Immunogen; SDS-PAGE; WB.
PAC195Hu01 Polyclonal Antibody to Sorting Nexin 13 (SNX13) WB; IHC
FAC195Hu01 Anti-Sorting Nexin 13 (SNX13) Polyclonal Antibody FCM
MAC195Hu22 Monoclonal Antibody to Sorting Nexin 13 (SNX13) WB; IHC; ICC; IP.
SEC195Hu ELISA Kit for Sorting Nexin 13 (SNX13) Enzyme-linked immunosorbent assay for Antigen Detection.
CMC195Hu Multiplex Assay Kit for Sorting Nexin 13 (SNX13) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMC195Hu Multiplex Assay Kit for Sorting Nexin 13 (SNX13) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.