Multiplex Assay Kit for Allograft inflammatory factor 1 (AIF1) ,etc. by CBA (Cytometric Bead Array)

IBA1; IRT1; Daintain; Protein G1; Ionized calcium-binding adapter molecule 1; G1

Specificity

This assay has high sensitivity and excellent specificity for detection of Allograft inflammatory factor 1 (AIF1) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Allograft inflammatory factor 1 (AIF1) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Allograft inflammatory factor 1 (AIF1) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Allograft inflammatory factor 1 (AIF1) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 98-105 101
EDTA plasma(n=5) 89-97 92
heparin plasma(n=5) 96-103 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Allograft inflammatory factor 1 (AIF1) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Allograft inflammatory factor 1 (AIF1) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Allograft inflammatory factor 1 (AIF1) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 94-103% 80-99% 88-102%
EDTA plasma(n=5) 96-104% 81-96% 82-94% 78-95%
heparin plasma(n=5) 78-91% 78-94% 93-101% 94-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Biosci Trends. Allograft inflammatory factor-1 in the pathogenesis of bleomycin-induced acute lung injury Pubmed:26911661
Cardiovasc Pathol A novel role for the Krüppel-like factor 14 on macrophage inflammatory response and atherosclerosis development pubmed:27923151
IOS Press Content Library An Intranasal Formulation of Erythropoietin (Neuro-EPO) Prevents Memory Deficits and Amyloid Toxicity in the APPSwe Transgenic Mouse Model of Alzheimer's … articles:journal-of-alzheimers-disease
博士论文 INSTITUTO DE CIENCIAS BÁSICAS Y PRECLÍNICAS “VICTORIA DE GIRÓN” DEPARTAMENTO DE HISTOLOGÍA
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
EPC288Mu61 Eukaryotic Allograft inflammatory factor 1 (AIF1) Positive Control; Immunogen; SDS-PAGE; WB.
RPC288Mu01 Recombinant Allograft inflammatory factor 1 (AIF1) Positive Control; Immunogen; SDS-PAGE; WB.
RPC288Mu02 Recombinant Allograft inflammatory factor 1 (AIF1) Positive Control; Immunogen; SDS-PAGE; WB.
PAC288Mu02 Polyclonal Antibody to Allograft inflammatory factor 1 (AIF1) WB; IHC; ICC; IP.
PAC288Mu01 Polyclonal Antibody to Allograft inflammatory factor 1 (AIF1) WB
LAC288Mu71 Biotin-Linked Polyclonal Antibody to Allograft inflammatory factor 1 (AIF1) WB
SEC288Mu ELISA Kit for Allograft inflammatory factor 1 (AIF1) Enzyme-linked immunosorbent assay for Antigen Detection.