Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Terminal Complement Complex C5b-9 (C5b-9) ,etc. by CBA (Cytometric Bead Array)
MAC; Membrane Attack Complex
- Product No.CMC350Rb
- Organism SpeciesOryctolagus cuniculus (Rabbit) Same name, Different species.
- Sample TypeSerum, plasma and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length4h
- Detection Range0.0586-60ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.0195ng/mL.
- DownloadInstruction Manual
- UOM 48T96T
- FOB
US$ 638
US$ 912
For more details, please contact local distributors!
Specificity
This assay has high sensitivity and excellent specificity for detection of Terminal Complement Complex C5b-9 (C5b-9) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Terminal Complement Complex C5b-9 (C5b-9) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Terminal Complement Complex C5b-9 (C5b-9) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Terminal Complement Complex C5b-9 (C5b-9) ,etc. by CBA (Cytometric Bead Array) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 88-101 | 93 |
| EDTA plasma(n=5) | 98-105 | 101 |
| heparin plasma(n=5) | 84-102 | 88 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Terminal Complement Complex C5b-9 (C5b-9) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Terminal Complement Complex C5b-9 (C5b-9) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Terminal Complement Complex C5b-9 (C5b-9) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 91-98% | 97-104% | 98-105% | 95-102% |
| EDTA plasma(n=5) | 82-102% | 99-105% | 89-101% | 91-99% |
| heparin plasma(n=5) | 88-96% | 88-95% | 80-94% | 91-103% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
| Magazine | Citations |
| Journal of Biomedical Materials Research Part A | Effect of thiol functionalization on the hemo-compatibility of PLGA nanoparticles Wiley: source |
| The Journal of Clinical Investigation | Complement component 5 contributes to poor disease outcome in humans and mice with pneumococcal meningitis PubMed: PMC3195471 |
| Colloids and Surfaces B: Biointerfaces | Glucosylated polymeric nanoparticles: A sweetened approach against blood compatibility paradox ScienceDirect: S0927776513001720 |
| Perfusion | The effect of normovolemic modified ultrafiltration on inflammatory mediators, endotoxins, terminal complement complexes and clinical outcome in high-risk cardiac surgery patients Pubmed: 23429100 |
| Nephrology Dialysis Transplantation | The efficacy of recombinant human soluble thrombomodulin for the treatment of shiga toxin associated hemolytic uremic syndrome model mice Pubmed:25694534 |
| journal of neuroinflammation | Adjuvant treatment with dexamethasone plus anti-C5 antibodies improves outcome of experimental pneumococcal meningitis: a randomized controlled trial PubMed: 26272468 |
| J Thromb Haemost | Thrombin‐activatable fibrinolysis inhibitor influences disease severity in humans and mice with pneumococcal meningitis PubMed: 26340319 |
| Digital Repository | Dosagem de frações ativadas do sistema complemento em empiema induzido em ratos 10183 |
| J Neuroinflammation. | Mannose-binding lectin-associated serine protease 2 (MASP-2) contributes to poor disease outcome in humans and mice with pneumococcal meningitis PMC5234106 |
| Cancer Letters | Complement C5a/C5aR pathway potentiates the pathogenesis Q5 of gastric cancer by down-regulating p21 expression pubmed:29031586 |
| Effects of immunoadsorption combined with membrane filtration on complement markers–Results of a randomized, controlled, crossover study | |
| Journal of Neuroinflammation | Complement factor H contributes to mortality in humans and mice with bacterial meningitis Pubmed: 31883521 |
| FASEB J | C‐reactive protein inhibits C3a/C3aR‐dependent podocyte autophagy in favor of diabetic kidney disease Pubmed:35503088 |
| Catalog No. | Related products for research use of Oryctolagus cuniculus (Rabbit) Organism species | Applications (RESEARCH USE ONLY!) |
| LMC350Rb | Multiplex Assay Kit for Terminal Complement Complex C5b-9 (C5b-9) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
| CMC350Rb | Multiplex Assay Kit for Terminal Complement Complex C5b-9 (C5b-9) ,etc. by CBA (Cytometric Bead Array) | FLIA Kit for Antigen Detection. |