Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Charcot Leyden Crystal Protein (CLC) ,etc. by CBA (Cytometric Bead Array)
LGALS10; LPPL; Eosinophil Lysophospholipase; Lysolecithin Acylhydrolase; Galectin 10
- Product No.CMC387Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.
- Test MethodDouble-antibody Sandwich
- Assay Length4h
- Detection Range0.0098-10ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.0033ng/mL.
- DownloadInstruction Manual
- UOM 48T96T
- FOB
US$ 605
US$ 864
For more details, please contact local distributors!
Specificity
This assay has high sensitivity and excellent specificity for detection of Charcot Leyden Crystal Protein (CLC) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Charcot Leyden Crystal Protein (CLC) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Charcot Leyden Crystal Protein (CLC) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Charcot Leyden Crystal Protein (CLC) ,etc. by CBA (Cytometric Bead Array) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 82-105 | 101 |
| EDTA plasma(n=5) | 78-102 | 98 |
| heparin plasma(n=5) | 95-102 | 99 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Charcot Leyden Crystal Protein (CLC) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Charcot Leyden Crystal Protein (CLC) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Charcot Leyden Crystal Protein (CLC) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 97-105% | 94-101% | 79-94% | 92-105% |
| EDTA plasma(n=5) | 88-95% | 89-97% | 80-101% | 97-104% |
| heparin plasma(n=5) | 89-98% | 87-96% | 98-105% | 80-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:CLC) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
| Magazine | Citations |
| Universit | Transcriptomics and Immune Profiles of Asymptomatic Filarial-Infected Individuals 2015: 4195 |
| Multiple Sclerosis and Related Disorders | Interleukin 1 receptor antagonist and 2′-5′-oligoadenylate synthetase-like molecules as novel biomarkers for multiple sclerosis patients in Bahrain pubmed:29141788 |
| INTERNATIONAL ARCHIVES OF ALLERGY AND IMMUNOLOGY | Predictive Significance of Charcot-Leyden Crystal Protein in Nasal Secretions in Recurrent Chronic Rhinosinusitis with Nasal Polyps Pubmed: 32927462 |
| INTERNATIONAL ARCHIVES OF ALLERGY AND IMMUNOLOGY | Charcot-Leyden Crystal Protein in Nasal Secretions of Patients with Nonallergic Rhinitis with Eosinophilia Syndrome Pubmed: 32694242 |
| Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
| RPC387Mu02 | Recombinant Charcot Leyden Crystal Protein (CLC) | Positive Control; Immunogen; SDS-PAGE; WB. |
| RPC387Mu01 | Recombinant Charcot Leyden Crystal Protein (CLC) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAC387Mu01 | Polyclonal Antibody to Charcot Leyden Crystal Protein (CLC) | WB; IHC; ICC; IP. |
| PAC387Mu02 | Polyclonal Antibody to Charcot Leyden Crystal Protein (CLC) | WB; IHC; ICC; IP. |
| SEC387Mu | ELISA Kit for Charcot Leyden Crystal Protein (CLC) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| CMC387Mu | Multiplex Assay Kit for Charcot Leyden Crystal Protein (CLC) ,etc. by CBA (Cytometric Bead Array) | FLIA Kit for Antigen Detection. |
| LMC387Mu | Multiplex Assay Kit for Charcot Leyden Crystal Protein (CLC) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |