Multiplex Assay Kit for Insulin Receptor Substrate 1 (IRS1) ,etc. by CBA (Cytometric Bead Array)

HIRS1

Specificity

This assay has high sensitivity and excellent specificity for detection of Insulin Receptor Substrate 1 (IRS1) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Insulin Receptor Substrate 1 (IRS1) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Insulin Receptor Substrate 1 (IRS1) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Insulin Receptor Substrate 1 (IRS1) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 99-105 102
EDTA plasma(n=5) 79-96 83
heparin plasma(n=5) 94-105 102

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Insulin Receptor Substrate 1 (IRS1) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Insulin Receptor Substrate 1 (IRS1) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Insulin Receptor Substrate 1 (IRS1) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 84-101% 98-105% 83-102% 91-101%
EDTA plasma(n=5) 83-101% 98-105% 80-98% 88-103%
heparin plasma(n=5) 95-105% 88-95% 84-105% 90-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
МЕДИЦИНСКИЙ ВЕСТНИК СЕВЕРНОГО КАВКАЗА Сравнительный анализ уровней антител к инсулиновым рецепторам у детей с сахарным диабетом i типа в зависимости от стадии заболевания article:n
Eur Neuropsychopharmacol. Regulation of insulin receptor phosphorylation in the brains of prenatally stressed rats: New insight into the benefits of antidepressant drug treatment. pubmed:28063625
Diabetes Lack of brain insulin receptor substrate-1 causes growth retardation, with decreased expression of growth hormone-releasing hormone in the hypothalamus. 33980693
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPC546Hu01 Recombinant Insulin Receptor Substrate 1 (IRS1) Positive Control; Immunogen; SDS-PAGE; WB.
PAC546Hu01 Polyclonal Antibody to Insulin Receptor Substrate 1 (IRS1) IHC; ICC/IF
MAC546Hu21 Monoclonal Antibody to Insulin Receptor Substrate 1 (IRS1) WB
SEC546Hu ELISA Kit for Insulin Receptor Substrate 1 (IRS1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC546Hu Multiplex Assay Kit for Insulin Receptor Substrate 1 (IRS1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMC546Hu Multiplex Assay Kit for Insulin Receptor Substrate 1 (IRS1) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.