Multiplex Assay Kit for Mitochondrial Uncoupling Protein 2 (UCP2) ,etc. by CBA (Cytometric Bead Array)

SLC25A8; UCPH; Solute carrier family 25 member 8 ;Uncoupling Protein 2, Mitochondrial

Specificity

This assay has high sensitivity and excellent specificity for detection of Mitochondrial Uncoupling Protein 2 (UCP2) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Mitochondrial Uncoupling Protein 2 (UCP2) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Mitochondrial Uncoupling Protein 2 (UCP2) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Mitochondrial Uncoupling Protein 2 (UCP2) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 97-105 102
EDTA plasma(n=5) 82-96 91
heparin plasma(n=5) 79-90 85

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mitochondrial Uncoupling Protein 2 (UCP2) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mitochondrial Uncoupling Protein 2 (UCP2) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mitochondrial Uncoupling Protein 2 (UCP2) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 81-96% 99-105% 85-96% 95-104%
EDTA plasma(n=5) 81-99% 98-105% 93-102% 80-105%
heparin plasma(n=5) 86-105% 83-104% 96-103% 96-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Stem Cells FM19G11 Favors Spinal Cord Injury Regeneration and Stem Cell Self-Renewal by Mitochondrial Uncoupling and Glucose Metabolism Induction PubMed: 22865656
Food Research International A 4-week consumption of medium roast and dark roast coffees affects parameters of energy status in healthy subjects Sciencedirect:S0963996914002403
The Journal of Maternal-Fetal & Neonatal Medicine The effect of delivery type on uncoupling protein-2 levels PubMed: 26479203
Life Sciences Vitamin C and E chronic supplementation differentially affect hepatic insulin signaling in rats Pubmed:29291420
REPRODUCTIVE TOXICOLOGY Dose-dependent reproductive toxicity of sodium benzoate in male rats: Inflammation, oxidative stress and apoptosis Pubmed: 32911041
Tissue Cell Vitamin B12 ameliorate Tramadol-induced oxidative stress, endocrine imbalance, apoptosis and NO/iNOS/NF-κB expression in Sprague Dawley through regulatory … 34923198
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPC586Mu01 Recombinant Mitochondrial Uncoupling Protein 2 (UCP2) Positive Control; Immunogen; SDS-PAGE; WB.
PAC586Mu01 Polyclonal Antibody to Mitochondrial Uncoupling Protein 2 (UCP2) WB; IHC
LAC586Mu71 Biotin-Linked Polyclonal Antibody to Mitochondrial Uncoupling Protein 2 (UCP2) WB
SEC586Mu ELISA Kit for Mitochondrial Uncoupling Protein 2 (UCP2) Enzyme-linked immunosorbent assay for Antigen Detection.
CMC586Mu Multiplex Assay Kit for Mitochondrial Uncoupling Protein 2 (UCP2) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMC586Mu Multiplex Assay Kit for Mitochondrial Uncoupling Protein 2 (UCP2) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSC586Mu01 ELISA Kit DIY Materials for Mitochondrial Uncoupling Protein 2 (UCP2) Main materials for "Do It(ELISA Kit) Yourself"