Multiplex Assay Kit for Osteoclast Associated Receptor (OSCAR) ,etc. by CBA (Cytometric Bead Array)

PIGR3; Osteoclast Associated,Immunoglobulin-Like Receptor; Polymeric immunoglobulin receptor 3; Poly-Ig receptor 3

Specificity

This assay has high sensitivity and excellent specificity for detection of Osteoclast Associated Receptor (OSCAR) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Osteoclast Associated Receptor (OSCAR) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Osteoclast Associated Receptor (OSCAR) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Osteoclast Associated Receptor (OSCAR) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 90-101 97
EDTA plasma(n=5) 83-97 87
heparin plasma(n=5) 99-105 102

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Osteoclast Associated Receptor (OSCAR) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Osteoclast Associated Receptor (OSCAR) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Osteoclast Associated Receptor (OSCAR) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 96-104% 91-98% 85-97% 79-91%
EDTA plasma(n=5) 81-105% 89-104% 78-89% 85-94%
heparin plasma(n=5) 86-97% 89-98% 81-98% 85-93%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Journal of Molecular and Cellular Cardiology Quantitative proteomics reveals novel functions of osteoclast-associated receptor in STAT signaling and cell adhesion in human endothelial cells PubMed: 22985931
Arthritis Research & Therapy The immunoreceptor tyrosine-based activation motif (ITAM) -related factors are increased in synovial tissue and vasculature of rheumatoid arthritic joints PubMed: 23146195
Inflammation Osteoclast-Associated Receptor (OSCAR) Distribution in the Synovial Tissues of Patients with Active RA and TNF-α and RANKL Regulation of Expression by Osteoclasts In Vitro article:10.1007
INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES Development of a novel polysaccharide-based iron oxide nanoparticle to prevent iron accumulation-related osteoporosis by scavenging reactive oxygen … Pubmed: 33049237
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPC695Hu01 Recombinant Osteoclast Associated Receptor (OSCAR) Positive Control; Immunogen; SDS-PAGE; WB.
CPC695Hu21 OVA Conjugated Osteoclast Associated Receptor (OSCAR) Immunogen; SDS-PAGE; WB.
PAC695Hu01 Polyclonal Antibody to Osteoclast Associated Receptor (OSCAR) WB; IHC; ICC; IP.
MAC695Hu21 Monoclonal Antibody to Osteoclast Associated Receptor (OSCAR) WB; IHC; ICC; IP.
MAC695Hu28 Monoclonal Antibody to Osteoclast Associated Receptor (OSCAR) WB; IHC; ICC; IP.
MAC695Hu23 Monoclonal Antibody to Osteoclast Associated Receptor (OSCAR) WB; IHC; ICC; IP.
MAC695Hu24 Monoclonal Antibody to Osteoclast Associated Receptor (OSCAR) WB; IHC; ICC; IP.
MAC695Hu25 Monoclonal Antibody to Osteoclast Associated Receptor (OSCAR) WB; IHC; ICC; IP.
MAC695Hu26 Monoclonal Antibody to Osteoclast Associated Receptor (OSCAR) WB; IHC; ICC; IP.
MAC695Hu22 Monoclonal Antibody to Osteoclast Associated Receptor (OSCAR) WB
SEC695Hu ELISA Kit for Osteoclast Associated Receptor (OSCAR) Enzyme-linked immunosorbent assay for Antigen Detection.
CEC695Hu ELISA Kit for Osteoclast Associated Receptor (OSCAR) Enzyme-linked immunosorbent assay for Antigen Detection.
CMC695Hu Multiplex Assay Kit for Osteoclast Associated Receptor (OSCAR) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMC695Hu Multiplex Assay Kit for Osteoclast Associated Receptor (OSCAR) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.