Multiplex Assay Kit for Claudin 3 (CLDN3) ,etc. by CBA (Cytometric Bead Array)

C7orf1; CPE-R2; CPETR2; HRVP1; RVP1; Clostridium Perfringens Enterotoxin Receptor 2; Ventral Prostate.1-Like Protein; CPE-Receptor 2

Specificity

This assay has high sensitivity and excellent specificity for detection of Claudin 3 (CLDN3) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Claudin 3 (CLDN3) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Claudin 3 (CLDN3) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Claudin 3 (CLDN3) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 88-102 92
EDTA plasma(n=5) 78-96 81
heparin plasma(n=5) 83-97 92

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Claudin 3 (CLDN3) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Claudin 3 (CLDN3) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Claudin 3 (CLDN3) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 87-95% 80-105% 91-101% 80-89%
EDTA plasma(n=5) 83-97% 94-101% 98-105% 82-95%
heparin plasma(n=5) 97-105% 78-101% 83-94% 83-97%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Eur J Appl Physiol Gastrointestinal response and endotoxemia during intense exercise in hot and cool environments Pubmed: 23314685
European Journal of Applied Physiology Effects of probiotics supplementation on gastrointestinal permeability, inflammation and exercise performance in the heat Springer: Source
Pediatr Crit Care Med Clinical Characteristics Associated With Postoperative Intestinal Epithelial Barrier Dysfunction in Children With Congenital Heart Disease* PubMed: 25162512
Clinical Nutrition Reinforcement of intestinal epithelial barrier by arabinoxylans in overweight and obese subjects: A randomized controlled trial: Arabinoxylans in gut barrier. pubmed:28214040
Clinics and Research in Hepatology and Gastroenterology Plasma claudin-3 is associated with tumor necrosis factor-alpha-induced intestinal endotoxemia in liver disease Pubmed: 31053499
Nutrients Intestinal Permeability in Children with Celiac Disease after the Administration of Oligofructose-Enriched Inulin into a Gluten-Free Diet—Results of a Randomized … Pubmed: 32531982
Journal of Exercise Physiology Online Markers of Intestinal Damage in Individuals with and without Obesity during a 12-Week Exercise Period.
JACC: Basic to Translational Science Dysbiosis and Intestinal Barrier Dysfunction in Pediatric Congenital Heart Disease is Exacerbated Following Cardiopulmonary Bypass
Nutrients Short-Term Very High Carbohydrate Diet and Gut-Training Have Minor Effects on Gastrointestinal Status and Performance in Highly Trained Endurance Athletes Pubmed:35565896
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPF293Hu01 Recombinant Claudin 3 (CLDN3) Positive Control; Immunogen; SDS-PAGE; WB.
CPF293Hu21 OVA Conjugated Claudin 3 (CLDN3) Immunogen; SDS-PAGE; WB.
PAF293Hu01 Polyclonal Antibody to Claudin 3 (CLDN3) WB; IHC; ICC; IP.
MAF293Hu21 Monoclonal Antibody to Claudin 3 (CLDN3) WB; IHC; ICC; IP.
SEF293Hu ELISA Kit for Claudin 3 (CLDN3) Enzyme-linked immunosorbent assay for Antigen Detection.
HEF293Hu High Sensitive ELISA Kit for Claudin 3 (CLDN3) Enzyme-linked immunosorbent assay for Antigen Detection.
LMF293Hu Multiplex Assay Kit for Claudin 3 (CLDN3) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMF293Hu Multiplex Assay Kit for Claudin 3 (CLDN3) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.