Multiplex Assay Kit for Nicotinamide Adenine Dinucleotide (NAD) ,etc. by CBA (Cytometric Bead Array)

Specificity

This assay has high sensitivity and excellent specificity for detection of Nicotinamide Adenine Dinucleotide (NAD) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Nicotinamide Adenine Dinucleotide (NAD) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of Nicotinamide Adenine Dinucleotide (NAD) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Nicotinamide Adenine Dinucleotide (NAD) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 97-105 101
EDTA plasma(n=5) 94-105 101
heparin plasma(n=5) 80-97 93

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Nicotinamide Adenine Dinucleotide (NAD) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Nicotinamide Adenine Dinucleotide (NAD) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Nicotinamide Adenine Dinucleotide (NAD) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 97-105% 91-99% 84-97% 85-99%
EDTA plasma(n=5) 80-98% 84-98% 99-105% 90-98%
heparin plasma(n=5) 98-105% 95-105% 80-104% 91-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:NAD) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 50μL standard or sample to each well, add 50μL prepared Detection Reagent A, add 10μL magnetic beads, and incubate 90 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
5. Wash plate once on magnetic frame;
6. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
neurotoxicology Targeting sirtuin activity with nicotinamide riboside reduces neuroinflammation in a GWI mouse model Pubmed: 32343995
Catalog No. Related products for research use of Pan-species (General) Organism species Applications (RESEARCH USE ONLY!)
CPG409Ge11 BSA Conjugated Nicotinamide Adenine Dinucleotide (NAD) Immunogen; SDS-PAGE; WB.
CPG409Ge21 OVA Conjugated Nicotinamide Adenine Dinucleotide (NAD) Immunogen; SDS-PAGE; WB.
PAG409Ge01 Polyclonal Antibody to Nicotinamide Adenine Dinucleotide (NAD) ELISA
CEG409Ge ELISA Kit for Nicotinamide Adenine Dinucleotide (NAD) Enzyme-linked immunosorbent assay for Antigen Detection.
LMG409Ge Multiplex Assay Kit for Nicotinamide Adenine Dinucleotide (NAD) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMG409Ge Multiplex Assay Kit for Nicotinamide Adenine Dinucleotide (NAD) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
KSG409Ge11 ELISA Kit DIY Materials for Nicotinamide Adenine Dinucleotide (NAD) Main materials for "Do It (ELISA Kit) Yourself".