Multiplex Assay Kit for Glutaminyl Peptide Cyclotransferase (QPCT) ,etc. by CBA (Cytometric Bead Array)

GCT; QC; EC; Glutaminyl Cyclase; Glutaminyl-tRNA cyclotransferase

Specificity

This assay has high sensitivity and excellent specificity for detection of Glutaminyl Peptide Cyclotransferase (QPCT) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Glutaminyl Peptide Cyclotransferase (QPCT) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Glutaminyl Peptide Cyclotransferase (QPCT) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Glutaminyl Peptide Cyclotransferase (QPCT) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 94-101 97
EDTA plasma(n=5) 92-99 96
heparin plasma(n=5) 85-99 95

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glutaminyl Peptide Cyclotransferase (QPCT) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glutaminyl Peptide Cyclotransferase (QPCT) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Glutaminyl Peptide Cyclotransferase (QPCT) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 95-103% 82-102% 86-93% 80-98%
EDTA plasma(n=5) 85-104% 93-105% 81-101% 81-97%
heparin plasma(n=5) 87-105% 96-105% 98-105% 78-97%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Journal of Alzheimer's Disease Increased glutaminyl cyclase expression in peripheral blood of Alzheimer's disease patients Pubmed: 23207485
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPH274Hu01 Recombinant Glutaminyl Peptide Cyclotransferase (QPCT) Positive Control; Immunogen; SDS-PAGE; WB.
APH274Hu01 Active Glutaminyl Peptide Cyclotransferase (QPCT) Cell culture; Activity Assays.
PAH274Hu01 Polyclonal Antibody to Glutaminyl Peptide Cyclotransferase (QPCT) WB
MAH274Hu21 Monoclonal Antibody to Glutaminyl Peptide Cyclotransferase (QPCT) WB
SEH274Hu ELISA Kit for Glutaminyl Peptide Cyclotransferase (QPCT) Enzyme-linked immunosorbent assay for Antigen Detection.
CMH274Hu Multiplex Assay Kit for Glutaminyl Peptide Cyclotransferase (QPCT) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMH274Hu Multiplex Assay Kit for Glutaminyl Peptide Cyclotransferase (QPCT) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.