Multiplex Assay Kit for Inter Alpha-Globulin Inhibitor H4 (ITIH4) ,etc. by CBA (Cytometric Bead Array)

IHRP; PK120; H4P; ITIHL1; Plasma Kallikrein-Sensitive Glycoprotein; Plasma kallikrein sensitive glycoprotein 120; Inter-alpha-trypsin inhibitor family heavy chain-related protein

Specificity

This assay has high sensitivity and excellent specificity for detection of Inter Alpha-Globulin Inhibitor H4 (ITIH4) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Inter Alpha-Globulin Inhibitor H4 (ITIH4) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Inter Alpha-Globulin Inhibitor H4 (ITIH4) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Inter Alpha-Globulin Inhibitor H4 (ITIH4) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 81-95 89
EDTA plasma(n=5) 79-94 89
heparin plasma(n=5) 96-104 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Inter Alpha-Globulin Inhibitor H4 (ITIH4) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Inter Alpha-Globulin Inhibitor H4 (ITIH4) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Inter Alpha-Globulin Inhibitor H4 (ITIH4) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 84-91% 92-101% 80-101% 78-93%
EDTA plasma(n=5) 94-105% 83-99% 82-95% 93-102%
heparin plasma(n=5) 79-102% 91-101% 85-94% 80-99%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Toxicology Letters Biomarkers for methotrexate-induced liver injury: urinary protein profiling of psoriasis patients. Pubmed: 23830989
International Journal of Medical Microbiology Proteomic demonstration of the recurrent presence of inter-alpha-inhibitor H4 heavy-chain during aspergillosis induced in an animal model Pubmed:24360996
Cancer Research and Treatment Inter-alpha Inhibitor H4 as a Potential Biomarker Predicting the Treatment Outcomes in Patients with Hepatocellular Carcinoma pubmed:28724284
Diagnostics Systemic Alterations of Immune Response-Related Proteins during Glaucoma Development in the Murine Model DBA/2J Pubmed: 32585848
Liver Cancer Biomarkers for locally advanced hepatocellular carcinoma patients treated with liver-directed combined radiotherapy
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPH776Mu01 Recombinant Inter Alpha-Globulin Inhibitor H4 (ITIH4) Positive Control; Immunogen; SDS-PAGE; WB.
RPH776Mu02 Recombinant Inter Alpha-Globulin Inhibitor H4 (ITIH4) Positive Control; Immunogen; SDS-PAGE; WB.
PAH776Mu01 Polyclonal Antibody to Inter Alpha-Globulin Inhibitor H4 (ITIH4) WB; IHC
PAH776Mu02 Polyclonal Antibody to Inter Alpha-Globulin Inhibitor H4 (ITIH4) WB; IHC; ICC; IP.
SEH776Mu ELISA Kit for Inter Alpha-Globulin Inhibitor H4 (ITIH4) Enzyme-linked immunosorbent assay for Antigen Detection.
LMH776Mu Multiplex Assay Kit for Inter Alpha-Globulin Inhibitor H4 (ITIH4) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMH776Mu Multiplex Assay Kit for Inter Alpha-Globulin Inhibitor H4 (ITIH4) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
KSH776Mu01 ELISA Kit DIY Materials for Inter Alpha-Globulin Inhibitor H4 (ITIH4) Main materials for "Do It(ELISA Kit) Yourself"