Multiplex Assay Kit for D-amino Acid Oxidase Activator (DAOA) ,etc. by CBA (Cytometric Bead Array)

G72; LG72; SG72

Specificity

This assay has high sensitivity and excellent specificity for detection of D-amino Acid Oxidase Activator (DAOA) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between D-amino Acid Oxidase Activator (DAOA) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant D-amino Acid Oxidase Activator (DAOA) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of D-amino Acid Oxidase Activator (DAOA) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-92 80
EDTA plasma(n=5) 78-104 96
heparin plasma(n=5) 90-103 95

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level D-amino Acid Oxidase Activator (DAOA) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level D-amino Acid Oxidase Activator (DAOA) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of D-amino Acid Oxidase Activator (DAOA) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-105% 84-94% 89-97% 97-104%
EDTA plasma(n=5) 92-105% 85-97% 94-102% 99-105%
heparin plasma(n=5) 80-96% 94-102% 95-102% 88-97%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
不确定杂志名 Age span expression of schizophrenia susceptibility genes D-amino acid oxidase (DAO) and DAO activator (DAOA) in human post-mortem brain dam:jcr:c3394762-a692-4fbd-8a37-7da14f429996
Frontiers in Neuroanatomy Expression of D-Amino Acid Oxidase (DAO/DAAO) and D-Amino Acid Oxidase Activator (DAOA/G72) during Development and Aging in the Human Post-mortem Brain. pubmed:28428746
Biomolecules Biochemical Properties and Physiological Functions of pLG72: Twenty Years of Investigations Pubmed:35740983
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPJ297Hu01 Recombinant D-amino Acid Oxidase Activator (DAOA) Positive Control; Immunogen; SDS-PAGE; WB.
PAJ297Hu01 Polyclonal Antibody to D-amino Acid Oxidase Activator (DAOA) WB; IHC; ICC; IP.
MAJ297Hu21 Monoclonal Antibody to D-amino Acid Oxidase Activator (DAOA) WB; IHC; ICC; IP.
SEJ297Hu ELISA Kit for D-amino Acid Oxidase Activator (DAOA) Enzyme-linked immunosorbent assay for Antigen Detection.
SCJ297Hu CLIA Kit for D-amino Acid Oxidase Activator (DAOA) Chemiluminescent immunoassay for Antigen Detection.
LMJ297Hu Multiplex Assay Kit for D-amino Acid Oxidase Activator (DAOA) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMJ297Hu Multiplex Assay Kit for D-amino Acid Oxidase Activator (DAOA) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.