Multiplex Assay Kit for Calponin 2 (CNN2) ,etc. by CBA (Cytometric Bead Array)

Neutral calponin; Calponin H2, smooth muscle

Specificity

This assay has high sensitivity and excellent specificity for detection of Calponin 2 (CNN2) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Calponin 2 (CNN2) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Calponin 2 (CNN2) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Calponin 2 (CNN2) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 84-101 93
EDTA plasma(n=5) 98-105 102
heparin plasma(n=5) 90-104 97

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Calponin 2 (CNN2) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Calponin 2 (CNN2) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Calponin 2 (CNN2) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 83-91% 98-105% 95-102% 97-104%
EDTA plasma(n=5) 89-97% 79-101% 91-99% 99-105%
heparin plasma(n=5) 81-90% 87-94% 82-104% 86-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Mol Med Rep Calponin PubMed: 25976781
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPJ410Hu01 Recombinant Calponin 2 (CNN2) Positive Control; Immunogen; SDS-PAGE; WB.
PAJ410Hu01 Polyclonal Antibody to Calponin 2 (CNN2) WB; IHC
MAJ410Hu22 Monoclonal Antibody to Calponin 2 (CNN2) WB
MAJ410Hu23 Monoclonal Antibody to Calponin 2 (CNN2) WB; ICC/IF
MAJ410Hu24 Monoclonal Antibody to Calponin 2 (CNN2) WB
MAJ410Hu25 Monoclonal Antibody to Calponin 2 (CNN2) IHC
MAJ410Hu21 Monoclonal Antibody to Calponin 2 (CNN2) WB
SEJ410Hu ELISA Kit for Calponin 2 (CNN2) Enzyme-linked immunosorbent assay for Antigen Detection.
CMJ410Hu Multiplex Assay Kit for Calponin 2 (CNN2) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMJ410Hu Multiplex Assay Kit for Calponin 2 (CNN2) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.