Multiplex Assay Kit for Protease, Serine 33 (PRSS33) ,etc. by CBA (Cytometric Bead Array)

EOS

Specificity

This assay has high sensitivity and excellent specificity for detection of Protease, Serine 33 (PRSS33) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Protease, Serine 33 (PRSS33) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Protease, Serine 33 (PRSS33) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Protease, Serine 33 (PRSS33) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 95-102 98
EDTA plasma(n=5) 99-105 102
heparin plasma(n=5) 85-101 91

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Protease, Serine 33 (PRSS33) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Protease, Serine 33 (PRSS33) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Protease, Serine 33 (PRSS33) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 89-96% 85-99% 79-89% 86-94%
EDTA plasma(n=5) 83-96% 97-105% 80-104% 78-99%
heparin plasma(n=5) 97-105% 88-95% 92-105% 94-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Allergol Int.  Human eosinophils constitutively express a unique serine protease, PRSS33. pubmed:28216055
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPS152Hu01 Recombinant Protease, Serine 33 (PRSS33) Positive Control; Immunogen; SDS-PAGE; WB.
PAS152Hu01 Polyclonal Antibody to Protease, Serine 33 (PRSS33) WB; IHC; ICC; IP.
MAS152Hu21 Monoclonal Antibody to Protease, Serine 33 (PRSS33) WB; IHC; ICC; IP.
SES152Hu ELISA Kit for Protease, Serine 33 (PRSS33) Enzyme-linked immunosorbent assay for Antigen Detection.
LMS152Hu Multiplex Assay Kit for Protease, Serine 33 (PRSS33) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMS152Hu Multiplex Assay Kit for Protease, Serine 33 (PRSS33) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.