Multiplex Assay Kit for Erythroferrone (ERFE) ,etc. by CBA (Cytometric Bead Array)

FAM132B; C1QTNF15; CTRP15; Myonectin; Family With Sequence Similarity 132, Member B; Complement C1q tumor necrosis factor-related protein 15

Specificity

This assay has high sensitivity and excellent specificity for detection of Erythroferrone (ERFE) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Erythroferrone (ERFE) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Erythroferrone (ERFE) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Erythroferrone (ERFE) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-104 97
EDTA plasma(n=5) 82-90 87
heparin plasma(n=5) 89-104 98

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Erythroferrone (ERFE) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Erythroferrone (ERFE) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Erythroferrone (ERFE) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 95-105% 79-105% 78-95% 79-93%
EDTA plasma(n=5) 87-97% 78-94% 96-104% 89-104%
heparin plasma(n=5) 93-102% 95-104% 88-95% 93-102%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
BRITISH JOURNAL OF HAEMATOLOGY Disordered serum erythroferrone and hepcidin levels as indicators of the spontaneous abortion occurrence during early pregnancy in humans Pubmed: 32866306
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPU540Hu01 Recombinant Erythroferrone (ERFE) Positive Control; Immunogen; SDS-PAGE; WB.
RPU540Hu02 Recombinant Erythroferrone (ERFE) Positive Control; Immunogen; SDS-PAGE; WB.
PAU540Hu01 Polyclonal Antibody to Erythroferrone (ERFE) Testing in progress
SEU540Hu ELISA Kit for Erythroferrone (ERFE) Enzyme-linked immunosorbent assay for Antigen Detection.
SCU540Hu CLIA Kit for Erythroferrone (ERFE) Chemiluminescent immunoassay for Antigen Detection.
LMU540Hu Multiplex Assay Kit for Erythroferrone (ERFE) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMU540Hu Multiplex Assay Kit for Erythroferrone (ERFE) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.