Multiplex Assay Kit for Urotensin 2 (UST2) ,etc. by FLIA (Flow Luminescence Immunoassay)

UII; U-II; UCN2; PRO1068; Urotensin-II

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Urotensin 2 (UST2) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Urotensin 2 (UST2) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Urotensin 2 (UST2) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Urotensin 2 (UST2) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 88-102 98
EDTA plasma(n=5) 83-95 89
heparin plasma(n=5) 92-101 97

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Urotensin 2 (UST2) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Urotensin 2 (UST2) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Urotensin 2 (UST2) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 81-96% 78-97% 80-95% 98-105%
EDTA plasma(n=5) 83-97% 84-98% 95-103% 89-103%
heparin plasma(n=5) 85-97% 83-97% 78-91% 87-94%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:UST2) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Clinical and Experimental Hypertension Serum Urotensin II Levels in Patients with Non-Dipper Hypertension Pubmed: 23301552
Peptides Urotensin II (U-II), a novel cyclic peptide, possibly associated with the pathophysiology of osteoarthritis Pubmed: 24468547
journal of diabetes and its complications Urotensin-II level and its association with oxidative stress in early diabetic nephropathy. pubmed:25179234
Evidence-based Complementary and Alternative Medicine  Acute Biochemical, Cardiovascular, and Autonomic Response to Hyperbaric (4 atm) Exposure in Healthy Subjects Pubmed:29977313
JOURNAL OF OCULAR PHARMACOLOGY AND THERAPEUTICS The Relationship of the Urotensin-2 Level in the Aqueous Humor with Systemic Diseases and Pupil Size: Comparative Study Pubmed: 33147089
Boy kısalığı olan çocukların serum ürotensin 2 düzeylerinin igf-1 ile ilişkisi.
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPA362Hu01 Recombinant Urotensin 2 (UST2) Positive Control; Immunogen; SDS-PAGE; WB.
CPA362Hu21 OVA Conjugated Urotensin 2 (UST2) Immunogen; SDS-PAGE; WB.
CPA362Hu31 KLH Conjugated Urotensin 2 (UST2) Immunogen; SDS-PAGE; WB.
PAA362Hu01 Polyclonal Antibody to Urotensin 2 (UST2) WB; IHC; ICC; IP.
PAA362Hu08 Polyclonal Antibody to Urotensin 2 (UST2) WB; IHC; ICC; IP.
LAA362Hu71 Biotin-Linked Polyclonal Antibody to Urotensin 2 (UST2) WB; IHC; ICC.
MAA362Hu22 Monoclonal Antibody to Urotensin 2 (UST2) WB; IHC; ICC; IP.
CEA362Hu ELISA Kit for Urotensin 2 (UST2) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA362Hu Multiplex Assay Kit for Urotensin 2 (UST2) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.