Multiplex Assay Kit for Glutathione S Transferase Omega 1 (GSTo1) ,etc. by FLIA (Flow Luminescence Immunoassay)

P28; GSTTLp28; GSTw1; SPG-R; Glutathione-dependent dehydroascorbate reductase; Monomethylarsonic acid reductase; MMA(V) reductase; S-(Phenacyl)glutathione reductase

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Glutathione S Transferase Omega 1 (GSTo1).
No significant cross-reactivity or interference between Glutathione S Transferase Omega 1 (GSTo1) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Glutathione S Transferase Omega 1 (GSTo1) and the recovery rates were calculated by comparing the measured value to the expected amount of Glutathione S Transferase Omega 1 (GSTo1) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 88-102 92
EDTA plasma(n=5) 99-105 102
heparin plasma(n=5) 82-91 87
sodium citrate plasma(n=5) 98-105 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glutathione S Transferase Omega 1 (GSTo1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glutathione S Transferase Omega 1 (GSTo1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Glutathione S Transferase Omega 1 (GSTo1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 81-96% 93-105% 85-96% 87-95%
EDTA plasma(n=5) 97-104% 98-105% 96-104% 81-98%
heparin plasma(n=5) 87-94% 86-97% 78-101% 96-103%
sodium citrate plasma(n=5) 84-98% 80-99% 96-104% 88-98%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:GSTo1) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
PLoS One Evaluation of surfactant proteins A, B, C, and D in articular cartilage, synovial membrane and synovial fluid of healthy as well as patients with osteoarthritis and … Pubmed: 30235245
American Journal of Respiratory and Critical Care Medicine Identification and Modulation of Microenvironment is Crucial for Effective MSC Therapy in Acute Lung Injury Pubmed: 30521764
Molecular Neurobiology Elevated levels of multifunctional surfactant proteins in cerebrospinal fluid are associated with signs of increased cerebrospinal fluid flow in cranial magnetic … Doi: 10.1007/s12035-017-0835-5
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPA623Mu01 Recombinant Glutathione S Transferase Omega 1 (GSTo1) Positive Control; Immunogen; SDS-PAGE; WB.
RPA623Mu02 Recombinant Glutathione S Transferase Omega 1 (GSTo1) Positive Control; Immunogen; SDS-PAGE; WB.
PAA623Mu02 Polyclonal Antibody to Glutathione S Transferase Omega 1 (GSTo1) WB; IHC; ICC; IP.
PAA623Mu01 Polyclonal Antibody to Glutathione S Transferase Omega 1 (GSTo1) WB; IHC
SEA623Mu ELISA Kit for Glutathione S Transferase Omega 1 (GSTo1) Enzyme-linked immunosorbent assay for Antigen Detection.
CMA623Mu Multiplex Assay Kit for Glutathione S Transferase Omega 1 (GSTo1) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMA623Mu Multiplex Assay Kit for Glutathione S Transferase Omega 1 (GSTo1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.