Multiplex Assay Kit for Chorionic Gonadotropin Alpha Polypeptide (CGa) ,etc. by FLIA (Flow Luminescence Immunoassay)
FSHA; GPHA1; GPHa; HCG; LHA; TSHA; Thyroid Stimulating Hormone Alpha; Follicle-Stimulating Hormone Alpha Subunit; Luteinizing hormone alpha chain; Lutropin alpha chain
(Note: Up to 8-plex in one testing reaction)
- Product No.LMB612Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length3h
- Detection Range9.77-10000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 3.257 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 387
US$ 402
US$ 424
US$ 454
US$ 484
US$ 528
US$ 595
US$ 744
Add to Price Calculator
Result
For more details, please contact local distributors!
Specificity
This assay has high sensitivity and excellent specificity for detection of Chorionic Gonadotropin Alpha Polypeptide (CGa).
No significant cross-reactivity or interference between Chorionic Gonadotropin Alpha Polypeptide (CGa) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Chorionic Gonadotropin Alpha Polypeptide (CGa) and the recovery rates were calculated by comparing the measured value to the expected amount of Chorionic Gonadotropin Alpha Polypeptide (CGa) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 94-104 | 97 |
| EDTA plasma(n=5) | 91-98 | 94 |
| heparin plasma(n=5) | 98-105 | 102 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Chorionic Gonadotropin Alpha Polypeptide (CGa) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Chorionic Gonadotropin Alpha Polypeptide (CGa) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Chorionic Gonadotropin Alpha Polypeptide (CGa) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 93-102% | 82-101% | 96-104% | 93-102% |
| EDTA plasma(n=5) | 80-102% | 87-104% | 87-98% | 92-101% |
| heparin plasma(n=5) | 86-101% | 80-91% | 90-99% | 83-90% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:CGa) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 50μL standard or sample to each well, add 50μL prepared Detection Reagent A, add 10μL magnetic beads, and incubate 90 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
5. Wash plate once on magnetic frame;
6. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.