Packages (Simulation)
 
Reagent Preparation
 
        Image (I)
Image (II)
Certificate
 
     
Multiplex Assay Kit for Syndecan 4 (SDC4) ,etc. by FLIA (Flow Luminescence Immunoassay)
SYND4; Amphiglycan; Ryudocan; Ryudocan core protein
(Note: Up to 8-plex in one testing reaction)
- Product No.LMB939Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range1.95-2000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.65 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
    
                                    US$ 450 
                                        US$ 468 
                                        US$ 494 
                                        US$ 528 
                                        US$ 563 
                                        US$ 615 
                                        US$ 693 
            
                
                        US$ 866 
                    
            Add to Price Calculator
            
            Result        
 For more details, please contact local distributors!
Specificity
                        This assay has high sensitivity and excellent specificity for detection of Syndecan 4 (SDC4) ,etc. by FLIA (Flow Luminescence Immunoassay).
                        No significant cross-reactivity or interference between Syndecan 4 (SDC4) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
                    
Recovery
Matrices listed below were spiked with certain level of recombinant Syndecan 4 (SDC4) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Syndecan 4 (SDC4) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
| Matrix | Recovery range (%) | Average(%) | 
| serum(n=5) | 86-96 | 89 | 
| EDTA plasma(n=5) | 79-88 | 84 | 
| heparin plasma(n=5) | 84-91 | 87 | 
| sodium citrate plasma(n=5) | 93-103 | 98 | 
Precision
                    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Syndecan 4 (SDC4) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively. 
                    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Syndecan 4 (SDC4) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate. 
                    CV(%) = SD/meanX100 
                    Intra-Assay: CV<10% 
                    Inter-Assay: CV<12% 
                
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Syndecan 4 (SDC4) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 | 
| serum(n=5) | 85-98% | 84-101% | 83-99% | 78-92% | 
| EDTA plasma(n=5) | 85-92% | 85-99% | 82-96% | 85-96% | 
| heparin plasma(n=5) | 93-102% | 78-89% | 99-105% | 90-97% | 
| sodium citrate plasma(n=5) | 83-97% | 96-103% | 95-105% | 80-96% | 
Stability
                    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. 
                    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
                
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity | 
| 96-well plate | 1 | Plate sealer for 96 wells | 4 | 
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL | 
| Pre-Mixed Magnetic beads (22#:SDC4) | 1 | Analysis buffer | 1×20mL | 
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL | 
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL | 
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL | 
| Instruction manual | 1 | 
Assay procedure summary
                    1. Preparation of standards, reagents and samples before the experiment;
                            2. Add 100μL standard or sample to each well, 
                                add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
                            3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
                            4. Wash plate on magnetic frame for three times;
                            5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
                            6. Wash plate on magnetic frame for three times;
                            7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
                
GIVEAWAYS
INCREMENT SERVICES
| Magazine | Citations | 
| Lipids in Health and Disease | The influence of atorvastatin on parameters of inflammation left ventricular function, hospitalizations and mortality in patients with dilated cardiomyopathy–5-year follow-up PubMed: PMC3641983 | 
| The FASEB Journal | Matrix metalloproteinase 9-mediated shedding of syndecan 4 in response to tumor necrosis factor α: a contributor to endothelial cell glycocalyx dysfunction Pubmed:25122554 | 
| Scientific Reports | Biomarkers and Echocardiographic Predictors of Myocardial Dysfunction in Patients with Hypertension PubMed: 25747153 | 
| Int J Mol Sci | The Multi-Biomarker Approach for Heart Failure in Patients with Hypertension PubMed: 25984599 | 
| Biochemical and Biophysical Research Communications | Syndecan-4 shedding impairs macrovascular angiogenesis in diabetes mellitus Pubmed:27018253 | 
| Kidney International | Aldosterone induces albuminuria via matrix metalloproteinase–dependent damage of the endothelial glycocalyx Pubmed: 30389198 | 
| Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) | 
| RPB939Ra01 | Recombinant Syndecan 4 (SDC4) | Positive Control; Immunogen; SDS-PAGE; WB. | 
| PAB939Ra01 | Polyclonal Antibody to Syndecan 4 (SDC4) | WB; IHC; ICC; IP. | 
| LAB939Ra71 | Biotin-Linked Polyclonal Antibody to Syndecan 4 (SDC4) | WB; IHC; ICC. | 
| LAB939Ra81 | FITC-Linked Polyclonal Antibody to Syndecan 4 (SDC4) | WB; IHC; ICC; IF. | 
| MAB939Ra21 | Monoclonal Antibody to Syndecan 4 (SDC4) | WB; IHC; ICC; IP. | 
| SEB939Ra | ELISA Kit for Syndecan 4 (SDC4) | Enzyme-linked immunosorbent assay for Antigen Detection. | 
| LMB939Ra | Multiplex Assay Kit for Syndecan 4 (SDC4) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. | 
 
         
                                     
                            