Packages (Simulation)
 
Reagent Preparation
 
        Image (I)
Image (II)
Certificate
 
     
Multiplex Assay Kit for Anandamide (AEA) ,etc. by FLIA (Flow Luminescence Immunoassay)
N-Arachidonoylethanolamine
(Note: Up to 8-plex in one testing reaction)
- Product No.LMO440Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- Sample TypeSerum, plasma and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length1.5h
- Detection Range0.2-200ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.067 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
    
                                    US$ 562 
                                        US$ 583 
                                        US$ 616 
                                        US$ 659 
                                        US$ 702 
                                        US$ 767 
                                        US$ 864 
            
                
                        US$ 1080 
                    
            Add to Price Calculator
            
            Result        
 For more details, please contact local distributors!
Specificity
                        This assay has high sensitivity and excellent specificity for detection of Anandamide (AEA) ,etc. by FLIA (Flow Luminescence Immunoassay).
                        No significant cross-reactivity or interference between Anandamide (AEA) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
                    
Recovery
Matrices listed below were spiked with certain level of Anandamide (AEA) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Anandamide (AEA) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
| Matrix | Recovery range (%) | Average(%) | 
| serum(n=5) | 87-95 | 91 | 
| EDTA plasma(n=5) | 85-95 | 90 | 
| heparin plasma(n=5) | 90-97 | 94 | 
| sodium citrate plasma(n=5) | 92-105 | 99 | 
Precision
                    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Anandamide (AEA) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively. 
                    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Anandamide (AEA) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate. 
                    CV(%) = SD/meanX100 
                    Intra-Assay: CV<10% 
                    Inter-Assay: CV<12% 
                
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Anandamide (AEA) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 | 
| serum(n=5) | 90-99% | 96-103% | 84-103% | 89-96% | 
| EDTA plasma(n=5) | 78-98% | 80-97% | 93-105% | 98-105% | 
| heparin plasma(n=5) | 78-90% | 88-96% | 88-97% | 78-95% | 
| sodium citrate plasma(n=5) | 95-102% | 80-102% | 81-101% | 99-105% | 
Stability
                    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. 
                    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
                
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity | 
| 96-well plate | 1 | Plate sealer for 96 wells | 4 | 
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL | 
| Pre-Mixed Magnetic beads (22#:AEA) | 1 | Analysis buffer | 1×20mL | 
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL | 
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL | 
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL | 
| Instruction manual | 1 | 
Assay procedure summary
                    1. Preparation of standards, reagents and samples before the experiment;
                            2. Add 50μL standard or sample to each well,
                                add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
                            3. Wash plate on magnetic frame for three times;
                            4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
                            5. Wash plate on magnetic frame for three times;
                            6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
                
GIVEAWAYS
INCREMENT SERVICES
| Magazine | Citations | 
| Journal of Sexual Medicine | Between pleasure and pain: a pilot study on the biological mechanisms associated with BDSM interactions in dominants and submissives Pubmed: 32044259 | 
| the journal of physiology | Modulatory effect of methanandamide on gastric vagal afferent satiety signals depends on nutritional status Pubmed: 32237243 | 
| Neuropharmacology | Role of PI3K/Akt axis in mitigating hippocampal ischemia-reperfusion injury via CB1 receptor stimulation by paracetamol and FAAH inhibitor in rat Pubmed:34968475 | 
| Parâmetros metabólicos, inflamatórios e de saciedade de gatos obesos alimentados com dieta com adição de beta-glucanos | 
| Catalog No. | Related products for research use of Pan-species (General) Organism species | Applications (RESEARCH USE ONLY!) | 
| CPO440Ge11 | BSA Conjugated Anandamide (AEA) | Immunogen; SDS-PAGE; WB. | 
| CPO440Ge21 | OVA Conjugated Anandamide (AEA) | Immunogen; SDS-PAGE; WB. | 
| PAO440Ge01 | Polyclonal Antibody to Anandamide (AEA) | ELISA | 
| CEO440Ge | ELISA Kit for Anandamide (AEA) | Enzyme-linked immunosorbent assay for Antigen Detection. | 
| LMO440Ge | Multiplex Assay Kit for Anandamide (AEA) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. | 
 
         
                                     
                            
