Multiplex Assay Kit for Glutathione S Transferase Alpha 1 (GSTa1) ,etc. by FLIA (Flow Luminescence Immunoassay)

GSTA1; GST2; GSTA1-1; GTH1; GST class-alpha member 1; GST HA subunit 1; GST-epsilon; Glutathione S-transferase A1, N-terminally processed

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Glutathione S Transferase Alpha 1 (GSTa1) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Glutathione S Transferase Alpha 1 (GSTa1) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Glutathione S Transferase Alpha 1 (GSTa1) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Glutathione S Transferase Alpha 1 (GSTa1) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-97 93
EDTA plasma(n=5) 81-95 87
heparin plasma(n=5) 81-102 85
sodium citrate plasma(n=5) 93-102 97

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glutathione S Transferase Alpha 1 (GSTa1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glutathione S Transferase Alpha 1 (GSTa1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Glutathione S Transferase Alpha 1 (GSTa1) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 92-99% 93-102% 97-104% 92-101%
EDTA plasma(n=5) 84-104% 84-104% 80-102% 88-95%
heparin plasma(n=5) 80-90% 87-95% 82-91% 84-101%
sodium citrate plasma(n=5) 81-89% 92-99% 92-101% 91-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:GSTa1) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
PLOS ONE Oviductal Transcriptome Is Modified after Insemination during Spontaneous Ovulation in the Sow PubMed: 26098421
Oxidative Medicine and Cellular Longevity Overexpression of Brg1 Alleviates Hepatic Ischemia/Reperfusion-Induced Acute Lung Injury through Antioxidative Stress Effects pubmed:28798861
Oxidative Medicine and Cellular Longevity Dexmedetomidine Attenuates Orthotopic Liver Transplantation-Induced Acute Gut Injury via α2-Adrenergic Receptor-Dependent Suppression of Oxidative Stress Pubmed: 31827710
Journal of Proteomics Complementary liver and serum protein profile in wild boars infected by the giant liver fluke Fascioloides magna using tandem mass tags quantitative approach 34298188
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPA609Mu01 Recombinant Glutathione S Transferase Alpha 1 (GSTa1) Positive Control; Immunogen; SDS-PAGE; WB.
RPA609Mu02 Recombinant Glutathione S Transferase Alpha 1 (GSTa1) Positive Control; Immunogen; SDS-PAGE; WB.
PAA609Mu02 Polyclonal Antibody to Glutathione S Transferase Alpha 1 (GSTa1) WB; IHC; ICC; IP.
PAA609Mu01 Polyclonal Antibody to Glutathione S Transferase Alpha 1 (GSTa1) WB; IHC; ICC; IP.
LAA609Mu71 Biotin-Linked Polyclonal Antibody to Glutathione S Transferase Alpha 1 (GSTa1) WB; IHC; ICC.
LAA609Mu81 FITC-Linked Polyclonal Antibody to Glutathione S Transferase Alpha 1 (GSTa1) WB; IHC; ICC; IF.
SEA609Mu ELISA Kit for Glutathione S Transferase Alpha 1 (GSTa1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA609Mu Multiplex Assay Kit for Glutathione S Transferase Alpha 1 (GSTa1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA609Mu01 ELISA Kit DIY Materials for Glutathione S Transferase Alpha 1 (GSTa1) Main materials for "Do It(ELISA Kit) Yourself"