Multiplex Assay Kit for Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay)

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity for detection of Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay).
100% cross-reactivity of Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay) was observed among Human, Mouse, Rat, Rabbit, Canine, Bovine.

Recovery

Matrices listed below were spiked with certain level of recombinant Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 91-101 98
EDTA plasma(n=5) 84-93 89
heparin plasma(n=5) 92-105 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-91% 78-101% 95-103% 96-105%
EDTA plasma(n=5) 91-98% 98-105% 86-97% 95-105%
heparin plasma(n=5) 93-101% 98-105% 78-101% 91-98%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:GLP1) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Diabetes, Obesity and Metabolism Specificity and sensitivity of commercially available assays for glucagon‐like peptide‐1 (GLP‐1): implications for GLP‐1 measurements in clinical studies Pubmed:25041349
Acta Histochemica Expression of cholecystokinin2-receptor in rat and human L cells and the stimulation of glucagon-like peptide-1 secretion by gastrin treatment Pubmed:25601282
Journal of Endocrinology Inhibitory effect of somatostatin on insulin secretion is not mediated via the CNS Pubmed:25630331
Obes Surg Effect of Sleeve Gastrectomy Plus Side-to-Side Jejunoileal Anastomosis for Type 2 Diabetes Control in an Obese Rat Model PubMed: 26202420
International Journal of Pharmacognosy and Phytochemical Research Anti-hiperglycemic Effect of Urena lobata Leaf Extract by Inhibition of Dipeptidyl Peptidase IV (DPP-IV) on Diabetic Rats Pdf: 7
European Journal of Pharmacology Subcutaneous administration of liraglutide ameliorates learning and memory impairment by modulating tau hyperphosphorylation via the glycogen synthase kinase-3尾 pathway in an amyloid 尾 protein induced alzheimer disease mouse model Pubmed:27131827
Int J Obes miR-200a reCavia (Guinea pig )lates Rheb-mediated amelioration of insulin resistance after duodenal-jejunal bypass Pubmed:27121251
Journal of Traditional and Complementary Medicine Incretin effect of Urena lobata leaves extract on structure and function of rats islet β-cells S2225411016302802
World Journal of Gastroenterology  Alterations in gut microbiota during remission and recurrence of diabetes after duodenal-jejunal bypass in rats pubmed:27547013
World Journal of Gastroenterology Effects of sleeve gastrectomy with jejuno-jejunal or jejuno-ileal loop onglycolipid metabolism in diabetic rats. pubmed:27621579
European Journal of Nutrition Improvement in glucose tolerance and insulin sensitivity by probiotic strains of Indian gut originin high-fat diet-fed C57BL/6J mice. pubmed:27757592
Journal of Traditional and Complementary Medicine  Incretin effect of Urena lobata leaves extract on structure and function of rats islet b-cells d69b5594c032d557c3f3203b91aba2604a94
Metabolism Deactivation of the NLRP3 inflammasome in infiltrating macrophages by duodenal-jejunal bypass surgery mediates improvement of beta cell function in type 2 diabetes 10.1016/j.metabol.2017.10.015
Obesity surgery The Effects of Duodenojejunal Omega Switch in Combination with High-Fat Diet and Control Diet on Incretins, Body Weight, and Glucose Tolerance in Sprague-Dawley Rats. pubmed:28840471
Obesity Surgery Selective Vagotomy Worsens Glucose Control After Ileal Transposition Pubmed:29525935
Obesity Surgery  Preserving Duodenal-Jejunal (Foregut) Transit Does Not Impair Glucose Tolerance and Diabetes Remission Following Gastric Bypass in Type 2 Diabetes Sprague … Pubmed:29098544
Frontiers in Physiology Ileal Transposition Surgery Decreases Fat Mass and Improves Glucose Metabolism in Diabetic GK Rats: Possible Involvement of FGF21 Pubmed:29593555
Journal of Physiology and Biochemistry Downregulation of lncRNA MALAT1 contributes to renal functional improvement after duodenal-jejunal bypass in a diabetic rat model Pubmed:29781038
Metabolism Deactivation of the NLRP3 inflammasome in infiltrating macrophages by duodenal-jejunal bypass surgery mediates improvement of beta cell function in type 2 … Pubmed:29129820
Nutrition in the Prevention and Treatment of Abdominal Obesity Effects of Diet-Induced Early-Stage Obesity on a Low-Testosterone Gottingen Minipig
Peptides The influence of high fat diet on plasma incretins and insulin concentrations in Sprague-Dawley rats with diet-induced obesity and glucose intolerance undergoing … Doi: 10.1016/j.peptides.2019.04.001
The Journal of Nutrition Grape Seed Proanthocyanidin Affects Lipid Metabolism via Changing Gut Microflora and Enhancing Propionate Production in Weaned Pigs Pubmed: 31175811
Neuropsychobiology Alcohol Withdrawal and Proopiomelanocortin Neuropeptides in an Animal Model of Alcohol Dependence Pubmed: 31117084
OBESITY SURGERY The Leading Role of Peptide Tyrosine Tyrosine in Glycemic Control After Roux-en-Y Gastric Bypass in Rats Pubmed: 31701411
Journal of Lipid Research Novel GPR120 agonist TUG891 modulates fat taste perception and preference and activates tongue-brain-gut axis in mice Pubmed: 31806728
Metabolik sendromlu sıçanlarda yüzme egzersizinin plazma glukagon-benzeri PEPTİD-1 (GLP-1) seviyesi ve hipokampal GLP-1 reseptörü üzerine etkisinin …
World J Diabetes Effect of oligofructose on resistance to postoperative high-fat diet-induced damage of metabolism in diabetic rats after sleeve gastrectomy 33889290
Study on the Therapeutic Effects of Traditional Chinese Medicine on Insulin Resistance in Obese Mice by Modulating Intestinal Function
Am J Physiol Endocrinol Metab Central GLP-1 contributes to improved cognitive function and brain glucose uptake after duodenum-jejunum bypass on obese and diabetic rats 34370593
Surgical Endoscopy The effect of bariatric surgery on the expression of Growth Differentiation Factor-15/Macrophage-Inhibitory Cytokine-1 (GDF-15/MIC-1) in rat Pubmed:35029766
Sci Rep The novel adamantane derivatives as potential mediators of inflammation and neural plasticity in diabetes mice with cognitive impairment Pubmed:35468904
Nutr Diabetes Response of blood glucose and GLP-1 to different food temperature in normal subject and patients with type 2 diabetes Pubmed:35624116
Different Estradiol Level's Impact on Appetite Regulation, Food Intake, and Concentrations of Leptin, Glucagon-Like Peptide-1, and High-Sensitivity C-Reactive …
Catalog No. Related products for research use of Homo sapiens (Human), Mus musculus (Mouse), Rattus norvegicus (Rat), Oryctolagus cuniculus (Rabbit), Canis familiaris; Canine (Dog), Bos taurus; Bovine (Cattle) Organism species Applications (RESEARCH USE ONLY!)
CPA804Mi22 OVA Conjugated Glucagon Like Peptide 1 (GLP1) Immunogen; SDS-PAGE; WB.
CPA804Mi21 OVA Conjugated Glucagon Like Peptide 1 (GLP1) Immunogen; SDS-PAGE; WB.
PAA804Mi01 Polyclonal Antibody to Glucagon Like Peptide 1 (GLP1) WB; IHC; ICC; IP.
MAA804Mi21 Monoclonal Antibody to Glucagon Like Peptide 1 (GLP1) WB; IHC; ICC; IP.
MEA804Mi Mini Samples ELISA Kit for Glucagon Like Peptide 1 (GLP1) Enzyme-linked immunosorbent assay for Antigen Detection.
CEA804Mi ELISA Kit for Glucagon Like Peptide 1 (GLP1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA804Mi Multiplex Assay Kit for Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.