Multiplex Assay Kit for Haptoglobin (Hpt) ,etc. by FLIA (Flow Luminescence Immunoassay)

HP; Hp2-Alpha; Alpha-2-Macroglobulin; Zonulin

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Haptoglobin (Hpt) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Haptoglobin (Hpt) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Haptoglobin (Hpt) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Haptoglobin (Hpt) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 95-104 101
EDTA plasma(n=5) 95-102 99
heparin plasma(n=5) 78-104 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Haptoglobin (Hpt) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Haptoglobin (Hpt) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Haptoglobin (Hpt) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 88-96% 91-98% 84-96% 95-102%
EDTA plasma(n=5) 78-102% 79-104% 93-105% 93-102%
heparin plasma(n=5) 89-104% 86-101% 78-95% 90-97%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:Hpt) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Journal of Vascular Surgery Circulation levels of acute phase proteins in patients with Takayasu arteritis PubMed: 20100644
Genetics Quantitative trait loci mapping of the mouse plasma proteome (pQTL). NCBI: PMC3567747
ostaglandins Leukot Essent Fatty Acids. Docosahexaenoic and eicosapentaenoic acid supplementation does not exacerbate oxidative stress or intravascular haemolysis in homozygous sickle cell patients. Pubmed: 24095588
PLoS One Gut Microbial Dysbiosis May Predict Diarrhea and Fatigue in Patients Undergoing Pelvic Cancer Radiotherapy: A Pilot Study PubMed: 25955845
Journal of Chromatography A Application of a new procedure for liquid chromatography/mass spectrometry profiling of plasma amino acid-related metabolites and untargeted shotgun proteomics to identify mechanisms and biomarkers of calcific aortic stenosis S0021967317311858
Annals of Neurology  High complement levels in astrocyte‐derived exosomes of Alzheimer disease Pubmed:29406582
European Journal of Medicinal Plants Effects of Hippophae rhamnoides L. Leaf and Marc Extract with Reduced Tannin Concentration on the Health and Growth Parameters of Newborn Calves
Journal of Animal Science Using ruminally protected and nonprotected active dried yeast as alternatives to antibiotics in finishing beef steers: growth performance, carcass traits, blood … Pubmed: 30184125
Journal of Clinical Medicine Urinary Proteomics for the Early Diagnosis of Diabetic Nephropathy in Taiwanese Patients Pubmed: 30486327
International Journal of Biological Sciences Generation of Pigs Resistant to Highly Pathogenic-Porcine Reproductive and Respiratory Syndrome Virus through Gene Editing of CD163
Food and Chemical Toxicology Prolyl endopeptidase-degraded low immunoreactive wheat flour attenuates immune responses in Caco-2 intestinal cells and gluten-sensitized BALB/c mice Pubmed: 31082461
Journal of Animal Science Ruminally protected and unprotected Saccharomyces cerevisiae fermentation products as alternatives to antibiotics in finishing beef steers Pubmed: 31410465
International Journal of Biological Sciences Deletion of CD163 Exon 7 Confers Resistance to Highly Pathogenic Porcine Reproductive and Respiratory Viruses on Pigs
Pediatric Obesity Intestinal permeability and small intestine bacterial overgrowth in excess weight adolescents Pubmed: 33089672
JOURNAL OF ANIMAL SCIENCE Processing Index of Barley Grain and Dietary Undigested Neutral Detergent Fiber Concentration Affected Chewing Behavior, Ruminal pH and Total Tract Nutrient?¡­ 33474564
large animal review Influence of niacin application on inflammatory parameters, non-esterified fatty acids and functional status of liver in cows during early lactation
PLoS One Could serum zonulin be an intestinal permeability marker in diabetes kidney disease? 34170951
Probiotics Antimicrob Proteins The Effect of Feed Supplementation with EM Bokashi® Multimicrobial Probiotic Preparation on Selected Parameters of Sow Colostrum and Milk as Indicators … 34596883
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPA817Hu01 Recombinant Haptoglobin (Hpt) Positive Control; Immunogen; SDS-PAGE; WB.
RPA817Hu03 Recombinant Haptoglobin (Hpt) Positive Control; Immunogen; SDS-PAGE; WB.
RPA817Hu02 Recombinant Haptoglobin (Hpt) Positive Control; Immunogen; SDS-PAGE; WB.
PAA817Hu01 Polyclonal Antibody to Haptoglobin (Hpt) WB; IHC; ICC; IP.
PAA817Hu03 Polyclonal Antibody to Haptoglobin (Hpt) WB; IHC; ICC; IP.
PAA817Hu02 Polyclonal Antibody to Haptoglobin (Hpt) WB; IHC
PAA817Hu04 Polyclonal Antibody to Haptoglobin (Hpt) WB; IHC; ICC; IP.
LAA817Hu71 Biotin-Linked Polyclonal Antibody to Haptoglobin (Hpt) WB; IHC; ICC.
MAA817Hu29 Monoclonal Antibody to Haptoglobin (Hpt) WB; IHC; ICC; IP.
MAA817Hu22 Monoclonal Antibody to Haptoglobin (Hpt) WB,IHC
MAA817Hu21 Monoclonal Antibody to Haptoglobin (Hpt) WB; IHC; ICC; IP.
MAA817Hu23 Monoclonal Antibody to Haptoglobin (Hpt) WB; IHC; ICC; IP.
MAA817Hu24 Monoclonal Antibody to Haptoglobin (Hpt) WB; IHC; ICC; IP.
MAA817Hu25 Monoclonal Antibody to Haptoglobin (Hpt) WB; IHC
MAA817Hu27 Monoclonal Antibody to Haptoglobin (Hpt) WB; IHC; ICC; IP.
MAA817Hu28 Monoclonal Antibody to Haptoglobin (Hpt) WB; IHC; ICC; IP.
MAA817Hu26 Monoclonal Antibody to Haptoglobin (Hpt) WB; IHC; ICC; IP.
FAA817Hu06 Anti-Haptoglobin (Hpt) Monoclonal Antibody FCM
FAA817Hu02 Anti-Haptoglobin (Hpt) Monoclonal Antibody Flow cytometry.
FAA817Hu04 Anti-Haptoglobin (Hpt) Monoclonal Antibody Flow cytometry.
LAA817Hu72 Biotin-Linked Monoclonal Antibody to Haptoglobin (Hpt) WB; IHC; ICC.
SEA817Hu ELISA Kit for Haptoglobin (Hpt) Enzyme-linked immunosorbent assay for Antigen Detection.
HEA817Hu High Sensitive ELISA Kit for Haptoglobin (Hpt) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA817Hu CLIA Kit for Haptoglobin (Hpt) Chemiluminescent immunoassay for Antigen Detection.
LMA817Hu Multiplex Assay Kit for Haptoglobin (Hpt) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
PSA817Hu01 Antibody Pair for Haptoglobin (Hpt) ELISA; CLIA; ELISPOT; Luminex; Immunochromatography and other Immunoassays.
KSA817Hu01 ELISA Kit DIY Materials for Haptoglobin (Hpt) Main materials for "Do It (ELISA Kit) Yourself".