Multiplex Assay Kit for Vitamin B6 (VB6) ,etc. by FLIA (Flow Luminescence Immunoassay)

Pyridoxine

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Vitamin B6 (VB6) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Vitamin B6 (VB6) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of Vitamin B6 (VB6) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Vitamin B6 (VB6) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 79-97 87
EDTA plasma(n=5) 85-98 91
heparin plasma(n=5) 89-97 93

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Vitamin B6 (VB6) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Vitamin B6 (VB6) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Vitamin B6 (VB6) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 88-104% 92-99% 79-95% 98-105%
EDTA plasma(n=5) 88-95% 96-103% 87-96% 78-95%
heparin plasma(n=5) 98-105% 80-89% 85-101% 78-88%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:VB6) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
PLoS ONE Campylobacter jejuni pdxA Affects Flagellum-Mediated Motility to Alter Host Colonization PubMed: PMC3735588
Nutrients Selected Risk Nutritional Factors for Chemotherapy-Induced Polyneuropathy. pubmed:28587059
Psychiatria Danubina HOMOCYSTEINE, PYRIDOXINE, FOLATE AND VITAMIN B12 LEVELS IN CHILDREN WITH ATTENTION DEFICIT HYPERACTIVITY DISORDER Pubmed: 30267523
Nutrients Physical Activity, Nutritional Status, and Autonomic Nervous System Activity in Healthy Young Adults with Higher Levels of Depressive Symptoms and Matched … Pubmed: 32143525
Catalog No. Related products for research use of Pan-species (General) Organism species Applications (RESEARCH USE ONLY!)
CPA916Ge41 HSA Conjugated Vitamin B6 (VB6) Immunogen; SDS-PAGE; WB.
CPA916Ge11 BSA Conjugated Vitamin B6 (VB6) Immunogen; SDS-PAGE; WB.
CPA916Ge21 OVA Conjugated Vitamin B6 (VB6) Immunogen; SDS-PAGE; WB.
PAA916Ge01 Polyclonal Antibody to Vitamin B6 (VB6) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
LAA916Ge71 Biotin-Linked Polyclonal Antibody to Vitamin B6 (VB6) WB; IHC; ICC.
MAA916Ge21 Monoclonal Antibody to Vitamin B6 (VB6) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
CEA916Ge ELISA Kit for Vitamin B6 (VB6) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA916Ge Multiplex Assay Kit for Vitamin B6 (VB6) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.