Multiplex Assay Kit for Agrin (AGRN) ,etc. by FLIA (Flow Luminescence Immunoassay)

Agrin Proteoglycan

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Agrin (AGRN).
No significant cross-reactivity or interference between Agrin (AGRN) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Agrin (AGRN) and the recovery rates were calculated by comparing the measured value to the expected amount of Agrin (AGRN) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 97-105 102
EDTA plasma(n=5) 91-101 96
heparin plasma(n=5) 89-96 93

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Agrin (AGRN) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Agrin (AGRN) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Agrin (AGRN) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 87-104% 90-98% 96-104% 94-105%
EDTA plasma(n=5) 80-89% 95-104% 96-103% 84-101%
heparin plasma(n=5) 92-101% 94-101% 87-101% 93-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:AGRN) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPB303Hu01 Recombinant Agrin (AGRN) Positive Control; Immunogen; SDS-PAGE; WB.
RPB303Hu02 Recombinant Agrin (AGRN) Positive Control; Immunogen; SDS-PAGE; WB.
PAB303Hu02 Polyclonal Antibody to Agrin (AGRN) IHC
PAB303Hu01 Polyclonal Antibody to Agrin (AGRN) IHC; ICC/IF
MAB303Hu22 Monoclonal Antibody to Agrin (AGRN) WB; IHC; ICC; IP.
SEB303Hu ELISA Kit for Agrin (AGRN) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB303Hu Multiplex Assay Kit for Agrin (AGRN) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMB303Hu Multiplex Assay Kit for Agrin (AGRN) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.