Multiplex Assay Kit for Lymphocyte Activation Gene 3 (LAG3) ,etc. by FLIA (Flow Luminescence Immunoassay)

CD223; Protein FDC

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Lymphocyte Activation Gene 3 (LAG3) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Lymphocyte Activation Gene 3 (LAG3) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Lymphocyte Activation Gene 3 (LAG3) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Lymphocyte Activation Gene 3 (LAG3) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 96-105 101
EDTA plasma(n=5) 88-101 95
heparin plasma(n=5) 91-99 96
sodium citrate plasma(n=5) 78-102 93

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Lymphocyte Activation Gene 3 (LAG3) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Lymphocyte Activation Gene 3 (LAG3) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Lymphocyte Activation Gene 3 (LAG3) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 83-103% 81-95% 97-105% 87-96%
EDTA plasma(n=5) 85-102% 91-99% 79-95% 95-103%
heparin plasma(n=5) 96-105% 78-105% 78-89% 79-92%
sodium citrate plasma(n=5) 83-94% 93-102% 78-103% 88-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:LAG3) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Biosensors and Bioelectronics A signal-decreased electrochemical immunosensor for the sensitive detection of LAG-3 protein based on a hollow nanobox-MOFs/AuPt alloy Pubmed:29772383
Cancer Biomarkers Soluble LAG3 acts as a potential prognostic marker of gastric cancer and its positive correlation with CD8+ T cell frequency and secretion of IL-12 and INF-γ in … Pubmed: 30223387
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPB663Hu01 Recombinant Lymphocyte Activation Gene 3 (LAG3) Positive Control; Immunogen; SDS-PAGE; WB.
RPB663Hu02 Recombinant Lymphocyte Activation Gene 3 (LAG3) Positive Control; Immunogen; SDS-PAGE; WB.
PAB663Hu01 Polyclonal Antibody to Lymphocyte Activation Gene 3 (LAG3) WB; IHC; ICC; IP.
MAB663Hu22 Monoclonal Antibody to Lymphocyte Activation Gene 3 (LAG3) WB; IHC; ICC; IP.
MAB663Hu21 Monoclonal Antibody to Lymphocyte Activation Gene 3 (LAG3) WB; IHC; ICC; IP.
RAB663Hu21 Recombinant Antibody to Lymphocyte Activation Gene 3 (LAG3) WB; IF; ICC; IHC; IP; FCM.
SEB663Hu ELISA Kit for Lymphocyte Activation Gene 3 (LAG3) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB663Hu Multiplex Assay Kit for Lymphocyte Activation Gene 3 (LAG3) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.