Multiplex Assay Kit for Interleukin 2 Receptor Alpha (IL2Ra) ,etc. by FLIA (Flow Luminescence Immunoassay)

CD25; IL2R-a; IL2-RA; IDDM10; IL2R; TCGFR; p55; TAC antigen

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Interleukin 2 Receptor Alpha (IL2Ra) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Interleukin 2 Receptor Alpha (IL2Ra) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Interleukin 2 Receptor Alpha (IL2Ra) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Interleukin 2 Receptor Alpha (IL2Ra) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 96-103 99
EDTA plasma(n=5) 96-105 101
heparin plasma(n=5) 78-92 83

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 2 Receptor Alpha (IL2Ra) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 2 Receptor Alpha (IL2Ra) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Interleukin 2 Receptor Alpha (IL2Ra) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 79-93% 80-97% 91-98% 87-105%
EDTA plasma(n=5) 98-105% 82-103% 92-105% 98-105%
heparin plasma(n=5) 97-104% 91-99% 93-101% 97-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:IL2Ra) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Journal of Microbiology, Immunology and Infection Identification of a panel of serum protein markers in early stage of sepsis and its validation in a cohort of patients pubmed:28655573
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPB837Hu01 Recombinant Interleukin 2 Receptor Alpha (IL2Ra) Positive Control; Immunogen; SDS-PAGE; WB.
APB837Hu61 Active Interleukin 2 Receptor Alpha (IL2Ra) Cell culture; Activity Assays.
EPB837Hu61 Eukaryotic Interleukin 2 Receptor Alpha (IL2Ra) Positive Control; Immunogen; SDS-PAGE; WB.
PAB837Hu01 Polyclonal Antibody to Interleukin 2 Receptor Alpha (IL2Ra) WB; ICC; IHC-P; IHC-F; ELISA.
FAB837Hu01 Anti-Interleukin 2 Receptor Alpha (IL2Ra) Polyclonal Antibody Flow cytometry.
FAB837Hu41 PE-Linked Anti-Interleukin 2 Receptor Alpha (IL2Ra) Polyclonal Antibody Flow cytometry.
FAB837Hu51 APC-Linked Anti-Interleukin 2 Receptor Alpha (IL2Ra) Polyclonal Antibody Flow cytometry.
FAB837Hu81 FITC-Linked Anti-Interleukin 2 Receptor Alpha (IL2Ra) Polyclonal Antibody Flow cytometry.
MAB837Hu27 Monoclonal Antibody to Interleukin 2 Receptor Alpha (IL2Ra) WB; IHC; ICC; IP.
RAB837Hu21 Recombinant Antibody to Interleukin 2 Receptor Alpha (IL2Ra) WB; IF; ICC; IHC; IP; FCM.
MAB837Hu29 Monoclonal Antibody to Interleukin 2 Receptor Alpha (IL2Ra) WB; IHC; ICC; IP.
MAB837Hu22 Monoclonal Antibody to Interleukin 2 Receptor Alpha (IL2Ra) WB; IHC; ICC; IP.
MAB837Hu26 Monoclonal Antibody to Interleukin 2 Receptor Alpha (IL2Ra) WB; IHC; ICC; IP.
MAB837Hu25 Monoclonal Antibody to Interleukin 2 Receptor Alpha (IL2Ra) WB; IHC; ICC; IP.
MAB837Hu21 Monoclonal Antibody to Interleukin 2 Receptor Alpha (IL2Ra) WB; IHC; ICC; IP.
MAB837Hu23 Monoclonal Antibody to Interleukin 2 Receptor Alpha (IL2Ra) WB; IHC; ICC; IP.
MAB837Hu24 Monoclonal Antibody to Interleukin 2 Receptor Alpha (IL2Ra) WB; IHC; ICC; IP.
RAB837Hu24 Recombinant Antibody to Interleukin 2 Receptor Alpha (IL2Ra) WB; IF; ICC; IHC; IP; FCM.
FAB837Hu02 Anti-Interleukin 2 Receptor Alpha (IL2Ra) Monoclonal Antibody FCM
FAB837Hu04 Anti-Interleukin 2 Receptor Alpha (IL2Ra) Monoclonal Antibody FCM
FAB837Hu86 FITC-Linked Anti-Interleukin 2 Receptor Alpha (IL2Ra) Monoclonal Antibody FCM
FAB837Hu42 PE-Linked Anti-Interleukin 2 Receptor Alpha (IL2Ra) Monoclonal Antibody FCM
FAB837Hu52 APC-Linked Anti-Interleukin 2 Receptor Alpha (IL2Ra) Monoclonal Antibody FCM
FAB837Hu82 FITC-Linked Anti-Interleukin 2 Receptor Alpha (IL2Ra) Monoclonal Antibody FCM
SEB837Hu ELISA Kit for Interleukin 2 Receptor Alpha (IL2Ra) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB837Hu Multiplex Assay Kit for Interleukin 2 Receptor Alpha (IL2Ra) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.