Multiplex Assay Kit for Carbonic Anhydrase III, Muscle Specific (CA3) ,etc. by FLIA (Flow Luminescence Immunoassay)

CA-III; CAIII; Car3; Carbonate dehydratase III

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Carbonic Anhydrase III, Muscle Specific (CA3).
No significant cross-reactivity or interference between Carbonic Anhydrase III, Muscle Specific (CA3) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Carbonic Anhydrase III, Muscle Specific (CA3) and the recovery rates were calculated by comparing the measured value to the expected amount of Carbonic Anhydrase III, Muscle Specific (CA3) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 95-105 99
EDTA plasma(n=5) 81-91 85
heparin plasma(n=5) 96-104 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Carbonic Anhydrase III, Muscle Specific (CA3) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Carbonic Anhydrase III, Muscle Specific (CA3) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Carbonic Anhydrase III, Muscle Specific (CA3) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 90-97% 78-99% 99-105%
EDTA plasma(n=5) 80-99% 78-101% 85-101% 91-101%
heparin plasma(n=5) 80-90% 92-102% 89-103% 93-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:CA3) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Biomarkers in Medicine Biochemical markers of muscle damage and high serum concentration of creatine kinase in patients on statin therapy Pubmed: 31157560
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPD070Hu01 Recombinant Carbonic Anhydrase III, Muscle Specific (CA3) Positive Control; Immunogen; SDS-PAGE; WB.
APD070Hu01 Active Carbonic Anhydrase III, Muscle Specific (CA3) Cell culture; Activity Assays.
PAD070Hu01 Polyclonal Antibody to Carbonic Anhydrase III, Muscle Specific (CA3) WB
LAD070Hu71 Biotin-Linked Polyclonal Antibody to Carbonic Anhydrase III, Muscle Specific (CA3) WB; IHC; ICC.
LAD070Hu81 FITC-Linked Polyclonal Antibody to Carbonic Anhydrase III, Muscle Specific (CA3) WB; IHC; ICC; IF.
MAD070Hu22 Monoclonal Antibody to Carbonic Anhydrase III, Muscle Specific (CA3) ICC/IF
MAD070Hu23 Monoclonal Antibody to Carbonic Anhydrase III, Muscle Specific (CA3) ICC/IF
MAD070Hu21 Monoclonal Antibody to Carbonic Anhydrase III, Muscle Specific (CA3) WB
FAD070Hu02 Anti-Carbonic Anhydrase III, Muscle Specific (CA3) Monoclonal Antibody FCM
FAD070Hu04 Anti-Carbonic Anhydrase III, Muscle Specific (CA3) Monoclonal Antibody FCM
LAD070Hu72 Biotin-Linked Monoclonal Antibody to Carbonic Anhydrase III, Muscle Specific (CA3) WB; IHC; ICC.
SED070Hu ELISA Kit for Carbonic Anhydrase III, Muscle Specific (CA3) Enzyme-linked immunosorbent assay for Antigen Detection.
CMD070Hu Multiplex Assay Kit for Carbonic Anhydrase III, Muscle Specific (CA3) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMD070Hu Multiplex Assay Kit for Carbonic Anhydrase III, Muscle Specific (CA3) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.