Multiplex Assay Kit for Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) ,etc. by FLIA (Flow Luminescence Immunoassay)

MAP1ALC3; MAP1BLC3; LC3; LC3A; ATG8E; Autophagy-related ubiquitin-like modifier LC3 A; MAP1 light chain 3-like protein 1

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-97 86
EDTA plasma(n=5) 81-95 92
heparin plasma(n=5) 79-97 83

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-91% 96-105% 99-105% 88-97%
EDTA plasma(n=5) 80-93% 78-92% 92-99% 87-104%
heparin plasma(n=5) 99-105% 80-98% 97-105% 92-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:MAP1LC3a) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
BRIEFINGS IN BIOINFORMATICS Lysosome activation in peripheral blood mononuclear cells and prognostic significance of circulating LC3B in COVID-19 33620066
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPL701Hu01 Recombinant Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) Positive Control; Immunogen; SDS-PAGE; WB.
PAL701Hu01 Polyclonal Antibody to Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) WB; IHC; ICC; IP.
MAL701Hu21 Monoclonal Antibody to Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) WB; IHC; ICC; IP.
SEL701Hu ELISA Kit for Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) Enzyme-linked immunosorbent assay for Antigen Detection.
LML701Hu Multiplex Assay Kit for Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.