Multiplex Assay Kit for Angiogenin (ANG) ,etc. by CBA (Cytometric Bead Array)

RNASE5; Ribonuclease,RNase A Family 5

Specificity

This assay has high sensitivity and excellent specificity for detection of Angiogenin (ANG) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Angiogenin (ANG) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Angiogenin (ANG) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Angiogenin (ANG) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 99-105 102
EDTA plasma(n=5) 78-93 87
heparin plasma(n=5) 95-102 99

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Angiogenin (ANG) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Angiogenin (ANG) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Angiogenin (ANG) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 83-96% 82-91% 90-97% 88-101%
EDTA plasma(n=5) 93-101% 80-105% 80-102% 91-103%
heparin plasma(n=5) 91-101% 82-104% 88-101% 78-91%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Inflammopharmacology Evening primrose oil and celecoxib inhibited pathological angiogenesis, inflammation, and oxidative stress in adjuvant-induced arthritis: novel role of angiopoietin-1 Pubmed: 24664592
Cancer Cell Angiogenin/Ribonuclease 5 is an EGFR ligand and a serum biomarker for erlotinib sensitivity in pancreatic cancer Pubmed:29606349
Journal of Immunotherapy The VE-PTP Inhibitor AKB-9778 Improves Antitumor Activity and Diminishes the Toxicity of Interleukin 2 (IL-2) Administration Pubmed: 31348125
Clinical Hemorheology and Microcirculation Nonselective alpha-/beta-AR antagonists can inhibit pericyte proliferation, migration, and secretion in vitro Pubmed: 32224529
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
APA007Mu02 Active Angiogenin (ANG) Cell culture; Activity Assays.
RPA007Mu01 Recombinant Angiogenin (ANG) Positive Control; Immunogen; SDS-PAGE; WB.
RPA007Mu02 Recombinant Angiogenin (ANG) Positive Control; Immunogen; SDS-PAGE; WB.
PAA007Mu01 Polyclonal Antibody to Angiogenin (ANG) IHC
PAA007Mu02 Polyclonal Antibody to Angiogenin (ANG) IHC
SEA007Mu ELISA Kit for Angiogenin (ANG) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA007Mu Multiplex Assay Kit for Angiogenin (ANG) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMA007Mu Multiplex Assay Kit for Angiogenin (ANG) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.