Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Meningioma Expressed Antigen 5 (MGEA5) ,etc. by CBA (Cytometric Bead Array)
NAGase; MEA5; NCOAT; Hexosaminidase C; N-Acetylhexosaminidase; Hyaluronidase; Meningioma-Expressed Antigen 5; Nuclear Cytoplasmic O-GlcNAcase And Acetyltransferase
- Product No.CMA069Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- Sample Typeurine, tissue homogenates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length4h
- Detection Range0.0977-100ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.0326ng/mL.
- DownloadInstruction Manual
- UOM 48T96T
- FOB
US$ 575
US$ 821
For more details, please contact local distributors!
Specificity
This assay has high sensitivity and excellent specificity for detection of Meningioma Expressed Antigen 5 (MGEA5) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Meningioma Expressed Antigen 5 (MGEA5) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Meningioma Expressed Antigen 5 (MGEA5) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Meningioma Expressed Antigen 5 (MGEA5) ,etc. by CBA (Cytometric Bead Array) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 78-94 | 89 |
| EDTA plasma(n=5) | 83-101 | 95 |
| heparin plasma(n=5) | 79-101 | 95 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Meningioma Expressed Antigen 5 (MGEA5) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Meningioma Expressed Antigen 5 (MGEA5) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Meningioma Expressed Antigen 5 (MGEA5) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 94-103% | 89-103% | 88-101% | 90-97% |
| EDTA plasma(n=5) | 97-105% | 93-103% | 87-103% | 87-101% |
| heparin plasma(n=5) | 90-101% | 88-104% | 82-93% | 95-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
| Magazine | Citations |
| Plos one | Metal-on-Metal Hip Prostheses and Systemic Health: A Cross-Sectional Association Study 8 Years after Implantation PubMed: PMC3677913 |
| Renal Failure | Evaluation of the Process of Recycling and Renal Parenchymal Injury after ESWL with Metabolites Excreted in the Urine Pubmed: 23413820 |
| BioMed Research International | The Renal Effects of Vanadate Exposure: Potential Biomarkers and Oxidative Stress as a Mechanism of Functional Renal Disorders—Preliminary Studies Hindawi: 740105 |
| PLoS One | Ameliorative Effect of Chrysin on Adenine-Induced Chronic Kidney Disease in Rats PubMed: 25909514 |
| Ecotoxicol Environ Saf | Melamine and oxalate coexposure induces early kidney tubular injury through mitochondrial aberrations and oxidative stress 34507040 |
| Antioxidants | Diminishment of Nrf2 Antioxidative Defense Aggravates Nephrotoxicity of Melamine and Oxalate Coexposure. Antioxidants 2021, 10, 1464 34573096 |

