Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Meningioma Expressed Antigen 5 (MGEA5) ,etc. by FLIA (Flow Luminescence Immunoassay)
NAGase; MEA5; NCOAT; Hexosaminidase C; N-Acetylhexosaminidase; Hyaluronidase; Meningioma-Expressed Antigen 5; Nuclear Cytoplasmic O-GlcNAcase And Acetyltransferase
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA069Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- Sample Typeurine
- Test MethodDouble-antibody Sandwich
- Assay Length4h
- Detection Range0.1-100ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.033 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 427
US$ 443
US$ 468
US$ 501
US$ 534
US$ 583
US$ 657
US$ 821
Add to Price Calculator
Result
For more details, please contact local distributors!
Specificity
This assay has high sensitivity and excellent specificity for detection of Meningioma Expressed Antigen 5 (MGEA5).
No significant cross-reactivity or interference between Meningioma Expressed Antigen 5 (MGEA5) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Meningioma Expressed Antigen 5 (MGEA5) and the recovery rates were calculated by comparing the measured value to the expected amount of Meningioma Expressed Antigen 5 (MGEA5) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 93-102 | 99 |
| EDTA plasma(n=5) | 85-95 | 90 |
| heparin plasma(n=5) | 78-96 | 92 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Meningioma Expressed Antigen 5 (MGEA5) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Meningioma Expressed Antigen 5 (MGEA5) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Meningioma Expressed Antigen 5 (MGEA5) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 86-96% | 87-95% | 78-97% | 88-102% |
| EDTA plasma(n=5) | 97-105% | 93-101% | 80-101% | 88-104% |
| heparin plasma(n=5) | 78-90% | 91-99% | 95-102% | 78-90% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:MGEA5) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
| Magazine | Citations |
| Plos one | Metal-on-Metal Hip Prostheses and Systemic Health: A Cross-Sectional Association Study 8 Years after Implantation PubMed: PMC3677913 |
| Renal Failure | Evaluation of the Process of Recycling and Renal Parenchymal Injury after ESWL with Metabolites Excreted in the Urine Pubmed: 23413820 |
| BioMed Research International | The Renal Effects of Vanadate Exposure: Potential Biomarkers and Oxidative Stress as a Mechanism of Functional Renal Disorders—Preliminary Studies Hindawi: 740105 |
| PLoS One | Ameliorative Effect of Chrysin on Adenine-Induced Chronic Kidney Disease in Rats PubMed: 25909514 |
| Ecotoxicol Environ Saf | Melamine and oxalate coexposure induces early kidney tubular injury through mitochondrial aberrations and oxidative stress 34507040 |
| Antioxidants | Diminishment of Nrf2 Antioxidative Defense Aggravates Nephrotoxicity of Melamine and Oxalate Coexposure. Antioxidants 2021, 10, 1464 34573096 |