OneStep ELISA Kit for Chemokine C-C-Motif Ligand 16 (CCL16)

SCYA16; SCYL4; LEC; HCC4; LMC; LCC1; CKb12; Mtn1; CC-4; Monotactin-1; IL-10-inducible chemokine; Liver-expressed chemokine; Lymphocyte and monocyte chemoattractant

Specificity

This assay has high sensitivity and excellent specificity for detection of Chemokine C-C-Motif Ligand 16 (CCL16).
No significant cross-reactivity or interference between Chemokine C-C-Motif Ligand 16 (CCL16) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Chemokine C-C-Motif Ligand 16 (CCL16) and the recovery rates were calculated by comparing the measured value to the expected amount of Chemokine C-C-Motif Ligand 16 (CCL16) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-96 86
EDTA plasma(n=5) 92-99 96
heparin plasma(n=5) 91-101 97

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Chemokine C-C-Motif Ligand 16 (CCL16) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Chemokine C-C-Motif Ligand 16 (CCL16) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Chemokine C-C-Motif Ligand 16 (CCL16) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 92-102% 80-103% 93-101% 96-103%
EDTA plasma(n=5) 78-89% 88-95% 78-94% 98-105%
heparin plasma(n=5) 98-105% 80-97% 87-101% 91-99%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well, then add 50µL prepared Detection Reagent A to each well. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
5. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
CELL BIOLOGY INTERNATIONAL Soluble CXCL16 Promotes TNF‐α‐induced Apoptosis in DLBCL via the AMAD10‐NF‐κB Regulatory Feedback Loop Pubmed: 31033093
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
APB126Hu01 Active Chemokine C-C-Motif Ligand 16 (CCL16) Cell culture; Activity Assays.
RPB126Hu01 Recombinant Chemokine C-C-Motif Ligand 16 (CCL16) Positive Control; Immunogen; SDS-PAGE; WB.
EPB126Hu51 Eukaryotic Chemokine C-C-Motif Ligand 16 (CCL16) Positive Control; Immunogen; SDS-PAGE; WB.
RPB126Hu02 Recombinant Chemokine C-C-Motif Ligand 16 (CCL16) Positive Control; Immunogen; SDS-PAGE; WB.
PAB126Hu07 Polyclonal Antibody to Chemokine C-C-Motif Ligand 16 (CCL16) WB; IHC; ICC; IP.
PAB126Hu01 Polyclonal Antibody to Chemokine C-C-Motif Ligand 16 (CCL16) IHC
PAB126Hu02 Polyclonal Antibody to Chemokine C-C-Motif Ligand 16 (CCL16) Testing in progress.
LAB126Hu71 Biotin-Linked Polyclonal Antibody to Chemokine C-C-Motif Ligand 16 (CCL16) WB; IHC; ICC.
SEB126Hu ELISA Kit for Chemokine C-C-Motif Ligand 16 (CCL16) Enzyme-linked immunosorbent assay for Antigen Detection.
OEB126Hu OneStep ELISA Kit for Chemokine C-C-Motif Ligand 16 (CCL16) Enzyme-linked immunosorbent assay for Antigen Detection.
CMB126Hu Multiplex Assay Kit for Chemokine C-C-Motif Ligand 16 (CCL16) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMB126Hu Multiplex Assay Kit for Chemokine C-C-Motif Ligand 16 (CCL16) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSB126Hu01 ELISA Kit DIY Materials for Chemokine C-C-Motif Ligand 16 (CCL16) Main materials for "Do It (ELISA Kit) Yourself".