OneStep ELISA Kit for Serum Amyloid A2 (SAA2)

SA-A2

Specificity

This assay has high sensitivity and excellent specificity for detection of Serum Amyloid A2 (SAA2).
No significant cross-reactivity or interference between Serum Amyloid A2 (SAA2) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Serum Amyloid A2 (SAA2) and the recovery rates were calculated by comparing the measured value to the expected amount of Serum Amyloid A2 (SAA2) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 88-98 94
EDTA plasma(n=5) 98-105 101
heparin plasma(n=5) 82-98 86

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Serum Amyloid A2 (SAA2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Serum Amyloid A2 (SAA2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Serum Amyloid A2 (SAA2) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 82-95% 87-97% 86-101% 79-97%
EDTA plasma(n=5) 90-103% 80-92% 92-105% 83-102%
heparin plasma(n=5) 97-105% 80-99% 87-97% 81-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well, then add 50µL prepared Detection Reagent A to each well. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
5. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Disease Models & Mechanisms Characterization of high-and low-risk hepatocellular adenomas by magnetic resonance in an animal model of glycogen storage disease type 1A Pubmed: 30898969
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
APB795Hu01 Active Serum Amyloid A2 (SAA2) Cell culture; Activity Assays.
RPB795Hu01 Recombinant Serum Amyloid A2 (SAA2) Positive Control; Immunogen; SDS-PAGE; WB.
PAB795Hu01 Polyclonal Antibody to Serum Amyloid A2 (SAA2) WB; IHC
MAB795Hu22 Monoclonal Antibody to Serum Amyloid A2 (SAA2) WB; IHC; ICC; IP.
SEB795Hu ELISA Kit for Serum Amyloid A2 (SAA2) Enzyme-linked immunosorbent assay for Antigen Detection.
OEB795Hu OneStep ELISA Kit for Serum Amyloid A2 (SAA2) Enzyme-linked immunosorbent assay for Antigen Detection.
CMB795Hu Multiplex Assay Kit for Serum Amyloid A2 (SAA2) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMB795Hu Multiplex Assay Kit for Serum Amyloid A2 (SAA2) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSB795Hu01 ELISA Kit DIY Materials for Serum Amyloid A2 (SAA2) Main materials for "Do It(ELISA Kit) Yourself"