OneStep ELISA Kit for Pregnancy Zone Protein (PZP)
CPAMD6; C3 and PZP-like alpha-2-macroglobulin domain-containing protein 6
- Product No.OEG324Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length1h10min
- Detection Range15.6-1,000ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 5.7ng/mL.
- DownloadInstruction Manual
- UOM 48T96T
- FOB
US$
US$
For more details, please contact local distributors!
Specificity
This assay has high sensitivity and excellent specificity for detection of Pregnancy Zone Protein (PZP).
No significant cross-reactivity or interference between Pregnancy Zone Protein (PZP) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Pregnancy Zone Protein (PZP) and the recovery rates were calculated by comparing the measured value to the expected amount of Pregnancy Zone Protein (PZP) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 81-101 | 95 |
| EDTA plasma(n=5) | 79-93 | 83 |
| heparin plasma(n=5) | 86-95 | 90 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Pregnancy Zone Protein (PZP) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Pregnancy Zone Protein (PZP) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Pregnancy Zone Protein (PZP) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 96-103% | 83-97% | 98-105% | 99-105% |
| EDTA plasma(n=5) | 96-103% | 78-91% | 83-97% | 98-105% |
| heparin plasma(n=5) | 88-96% | 86-97% | 80-92% | 79-90% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well, then add 50µL prepared Detection Reagent A to each well. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
5. Add 50µL Stop Solution. Read at 450nm immediately.